4-17
Cisco TelePresence System 1100 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-19695-01
Chapter 4 First-Time Setup
Setting Up the Camera
Positioning the Table and Starting the Calibration Procedure
To correctly position the table and configure the Cisco TelePresence software for use with the CTS 1100
camera, complete the following procedure.
Step 1
Position the table so that it fulfills the following requirements:
•
The front edge of the table is a minimum of 44 inches (112 cm) away from the display.
•
The sides of the table are evenly positioned on each side of the CTS 1100.
•
The rear edge of the table is between eight and 12 feet (244 and 366 cm) away from the display.
Note
The table must be 28 to 32 inches (71 to 81 cm) high; 30 inches (76 cm) is the optimal height.
Figure 4-10
Table Positioning
Performing Initial Focus Adjustments and Adjusting the Camera Zoom
To adjust the zoom and perform initial focus adjustment for the camera, complete the steps in the
following procedure.
Step 1
Place the large camera target with the easel in the position where the two participants will sit, with the
front legs of the easel touching the edge of the table.
Step 2
Measure the distance between the corners of the easel and the corners of the display to make sure that
the target is parallel to the display.
A
B
A=B
44 inches
(112 cm)
minim
u
m
8
feet (244 cm) recommended,
12 feet (366 cm) m
a
xim
u
m)
206615
30 inches (76 cm)
between p
a
rticip
a
nts
1
8
inches
(46 cm)