1-4
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
OL-25303-03
Chapter 1 Configuring Port-Based Traffic Control
Configuring Storm Control
Step 3
storm-control
{
broadcast
|
multicast
|
unicast
}
level
{
level
[
level-low
] |
bps
bps
[
bps-low
] |
pps
pps
[
pps-low
]}
Configure broadcast, multicast, or unicast storm control. By
default, storm control is disabled.
The keywords have these meanings:
•
For
level
, specify the rising threshold level for broadcast,
multicast, or unicast traffic as a percentage (up to two decimal
places) of the bandwidth. The port blocks traffic when the
rising threshold is reached. The range is 0.00 to 100.00.
•
(Optional) For
level-low
, specify the falling threshold level as
a percentage (up to two decimal places) of the bandwidth. This
value must be less than or equal to the rising suppression
value. The port forwards traffic when traffic drops below this
level. If you do not configure a falling suppression level, it is
set to the rising suppression level. The range is 0.00 to 100.00.
If you set the threshold to the maximum value (100 percent),
no limit is placed on the traffic. If you set the threshold to 0.0,
all broadcast, multicast, and unicast traffic on that port is
blocked.
•
For
bps
bps
, specify the rising threshold level for broadcast,
multicast, or unicast traffic in bits per second (up to one
decimal place). The port blocks traffic when the rising
threshold is reached. The range is 0.0 to 10000000000.0.
•
(Optional) For
bps-low
, specify the falling threshold level in
bits per second (up to one decimal place). It can be less than or
equal to the rising threshold level. The port forwards traffic
when traffic drops below this level. The range is 0.0 to
10000000000.0.
•
For
pps
pps
, specify the rising threshold level for broadcast,
multicast, or unicast traffic in packets per second (up to one
decimal place). The port blocks traffic when the rising
threshold is reached. The range is 0.0 to 10000000000.0.
•
(Optional) For
pps-low
, specify the falling threshold level in
packets per second (up to one decimal place). It can be less
than or equal to the rising threshold level. The port forwards
traffic when traffic drops below this level. The range is
0.0 to
10000000000.0
.
For BPS and PPS settings, you can use metric suffixes such as k,
m, and g for large number thresholds.
Step 4
storm-control action
{
shutdown
|
trap
}
Specify the action to be taken when a storm is detected. The default
is to filter out the traffic and not to send traps.
•
Select the
shutdown
keyword to error-disable the port during
a storm.
•
Select the
trap
keyword to generate an SNMP trap when a
storm is detected.
Step 5
end
Return to privileged EXEC mode.
Command
Purpose
Summary of Contents for Catalyst 3560-X Series
Page 12: ...Contents 10 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 13: ...Contents 11 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 14: ...Contents 12 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 15: ...Contents 13 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 16: ...Contents 14 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 17: ...Contents 15 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 18: ...Contents 16 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 19: ...Contents 17 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 20: ...Contents 18 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 21: ...Contents 19 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 22: ...Contents 20 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 23: ...Contents 21 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 24: ...Contents 22 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 25: ...Contents 23 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 26: ...Contents 24 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 27: ...Contents 25 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 28: ...Contents 26 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 29: ...Contents 27 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 30: ...Contents 28 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 31: ...Contents 29 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 32: ...Contents 30 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 33: ...Contents 31 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 34: ...Contents 32 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 35: ...Contents 33 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 36: ...Contents 34 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 37: ...Contents 35 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 38: ...Contents 36 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...
Page 42: ...56 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 Preface ...
Page 1538: ...Index IN 58 Catalyst 3750 X and 3560 X Switch Software Configuration Guide OL 25303 03 ...