ChargePoint® Charging Stations
A-2
Safety and Operational Ratings
Indicators
ChargePoint, Inc. reserves the right to alter product offerings and specifications at any time without notice, and is not responsible for
typographical or graphical errors that may appear in this document.
Enclosure Ratings
Type 3R per UL 50E
Safety and Compliance
UL and C-UL listed product per UL2594, UL2231-1, UL2231-2. NEC Article 625 compliant
Surge Protection
6kV @ 3000A. In geographic areas subject to frequent thunder storms, supplemental surge
protection at the service panel is recommended.
EMC Compliance
FCC Part 15 Class B
Storage Temperature
-40°F to 140°F (-40°C to +60°C)
Operating Temperature
22°F to 122°F (-30°C to +50°C)
Operating Humidity
Up to 85% @ 122°F (+50°C) non-condensing
Non-Operating Humidity
Up to 95% at 50°C non-condensing
Maximum Charging Stations per
802.11 Radio Group
9. Each station must be located within 150 feet “line of sight” of a CPGWx gateway.
WiFi LED
Yes
Fault Indicator per UL
Yes
Status LED
Yes