Emotron VS Series Quick Start Guide
- 86 -
defined
A0.21
Inverter rated voltage
Range:60
~
660V
Default: Model
defined
A0.22
Inverter rated current
Range:0.1
~
1500.0A
Default: Model
defined
A0.23
Software version
Range:0.00
~
999.99
Default: Model
defined
The parameters are only for reference and cannot be edited.
A0.24
Dealer password
Range: 0
~
65535
Default: 0
A0.25
Operation time
Range: 0
~
65535h(0:
Invalid)
Default: 0
When total running time ≥A0.25, inverter will not work. When setting A0.24, need to unlock A0.24
dealer passport, after time setting, need to input dealer passport to lock.
★
: Setting this parameter may cause that the inverter can’t work normally, please set carefully.
Group b0 Frequency command
Master frequency
source
Auxiliary
frequency source
Terminal UP
/DOWN
+
+
-
Max
Min
+
x
+
AI1
x
AI2
0
1
2
3
4
5
6
7
Switched by
terminal
Switched by
terminal
Jog
frequency
Command frequency
Fig 6-1
b0.00
Frequency source
selection
Range:0
~
7
Default: 0
0: Master frequency source
The frequency source is determined by master frequency source b0.01.
1: Auxiliary frequency source
The frequency source is determined by auxiliary frequency source b0.03.
2: Auxiliary
The frequency source is determined by Auxiliary.
3: Master - Auxiliary
The frequency source is determined by Master - Auxiliary.
4: MAX {Master, Auxiliary}
The frequency source is determined by MAX {Master, Auxiliary}.
5: MIN {Master, Auxiliary}
The frequency source is determined by MIN {Master, Auxiliary}.
6:
Auxiliary)
The frequency source is determined by AI1*( Auxiliary).
7: AI2
Auxiliary)
The frequency source is determined by AI2*( Auxiliary).
b0.01
Master frequency source selection
Range:0
~
9
VSX: Default:0
Others: Default:1