Emotron VS Series Quick Start Guide
- 161 -
0
:
Invalid
When light load direction detection completed, inverter run via light load direction
1
:
Valid
When detecting light load direction, when UPS power voltages in both direction are lower than
setting of y0.28, inverter will trip with Err43
y0.30
Emergency mode frequency given
by terminal
0: Invalid
Default: 1
1: Valid
0: Invalid
In emergency mode, frequency is given by y0.12
1
:
Valid
In emergency mode, when terminal given is invalid, given frequency is 0Hz, when terminal given
valid, frequency given by y0.12
y0.31
Emergency mode intelligent drive
output
0
:
Invalid
Default: 1
1
:
Valid
0
:
Invalid
In emergency mode, inverter output according to the setting drive mode
1
:
Valid
In emergency mode, inverter output via setting of y0.32
y0.32
Emergency mode output
percentage
0.0
~
100.0%
Default:
100.0%
Used for setting output percentage when y0.31=1
y0.34
Err41 overload times setting
0
~
5
Default: 2
y0.35
Err41 times interval time
0
~
1000Min
Default:60Min
y0.36
Err41 overload reset time
0
~
1000s
Default: 120s
y0.37
Err41 overload reset time timing
0
~
1000s
Default: 0s
y0.38
Err41 overload times
0
~
5
Default: 0
When Err41 overload fault, system will record Err41 overload fault times which is displayed in
y0.38. When fault reset, if no again Err41 within setting time (y0.35), zero clearance in y0.38; If again
Err41 within setting time y0.35, the value will be accumulated in y0.38, when the value y0.38 is bigger
than the value y0.34, system will forbid Err41 reset, only after setting time y0.36 can reset Err41. y0.37
FOR reset time timing.
b2.11
S curve Time 1
0.00
~
600.00s
Default:1.00s
b2.15
S curve Time 2
0.00
~
600.00s
Default:1.00s
b2.16
S curve Time 3
0.00
~
600.00s
Default:1.00s
b2.17
S curve Time 4
0.00
~
600.00s
Default:1.00s
y0.39
S curve Time 5
0.00
~
60.00s
Default:1.00s
y0.40
S curve Time 6
0.00
~
60.00s
Default:0.50s
S curve time setting:
y0.05
High
Speed
DC injection
Leveling
Speed
b2.11
b2.15
b2.16
b2.17
y0.39
y0.40
Hz