Emotron VS Series Quick Start Guide
- 162 -
y0.41
Coefficient of S curve time when
short floor function is enabled
0.00
~
1.00
Default: 0.7
When short floor function is enabled and triggered, deceleration time will multiple this coefficient
set by y0.41.
Special DI/DO terminal function for Elevator inverter
Function Code
Description
Terminal function
C0.00~C0.09
Digital input terminals
50:Special purpose inverter enable
51: Elevator maintenance signal
52: Elevator emergency signal
C1.00~C1.03
Digital output terminals
60:Elevator brake output
61: Operation contactor output
62: Emergency signal timecompleted
63: Light load direction search
64: Light load direction search direction
Special fault type for Elevator inverter
ERROR
Description
Err43
Light load search failure
8.2.Multi-step speed setting method
In different elevator controllers, the combination difference of multi-step speed terminal output
signal will cause the parameter setting difference of leveling speed and high speed, please refer to
below diagram for the parameter setting:
Table1
multi-step speed terminal function
DI4(C0.03=14)
DI3(C0.02=13)
Speed setting parameter
0
0
F1.00
0
1
F1.01
1
0
F1.02
1
1
F1.03
Speed parameter of group F1 will be set by percentage, 100.0% corresponded to maximum
frequency (Setting value of b0.08),meanwhile every step speed can be acceleration time and
deceleration time independently, please refer to below diagram for the details
Multi step speed
Parameter for
selecting accel and
decel time
F1.00
F1.34
F1.01
F1.35
F1.02
F1.36
F1.03
F1.37