![CG Emotron VFX Series Instruction Manual Download Page 99](http://html1.mh-extra.com/html/cg/emotron-vfx-series/emotron-vfx-series_instruction-manual_2585388099.webp)
CG Drives & Automation,01-5326-01r5
Functional Description
95
To prevent the keyboard being used or to change the setup
of the AC drive and/or process control, the keyboard can be
locked with a password. This menu, “Lock Code [218]”, is
used to lock and unlock the keyboard. Enter the password
“291” to lock/unlock the keyboard operation. If the
keyboard is not locked (default) the selection “Lock Code?”
will appear. If the keyboard is already locked, the selection
“Unlock Code?” will appear.
When the keyboard is locked, parameters can be viewed but
not changed. The reference value can be changed and the
AC drive can be started, stopped and reversed if these
functions are set to be controlled from the keyboard.
Communication information
Overall limitation of motor rotation
direction
This function limits the overall rotation, either to left or
right or both directions. This limit is prior to all other
selections, e.g.: if the rotation is limited to right, a Run-Left
command will be ignored. To define left and right rotation
we assume that the motor is connected U-U, V-V and W-W.
Speed Direction and Rotation
The speed direction can be controlled by:
•
RunR/RunL commands on the control panel.
•
RunR/RunL commands on the terminal strip
(terminals 1-22).
•
Via the serial interface options.
•
The parameter sets.
Fig. 93 Rotation
In this menu you set the general rotation for the motor.
Communication information
218
Lock code?
Default:
0
Range:
0–9999
Modbus Instance no/DeviceNet no:
43018
Profibus slot/index
168/177
EtherCAT and CANopen index (hex)
4bca
Profinet IO index
19402
Fieldbus format
UInt, 1=1
Modbus format
UInt
219
Rotation
Default:
R + L
R
1
Speed direction is limited to right
rotation. The input and key RunL are
disabled.
L
2
Speed direction is limited to left rotation.
The input and key RunR are disabled.
R+L
3
Both speed directions allowed.
Modbus Instance no/DeviceNet no:
43019
Profibus slot/index
168/178
EtherCAT and CANopen index (hex)
4bcb
Profinet IO index
19403
Fieldbus format
UInt
Modbus format
UInt
Right
Left
Summary of Contents for Emotron VFX Series
Page 1: ...Emotron VFX 2 0 AC drive Instruction manual English Valid from software version 4 42...
Page 2: ......
Page 4: ......
Page 10: ...6 CG Drives Automation 01 5326 01r5...
Page 50: ...46 Installation CG Drives Automation 01 5326 01r5...
Page 62: ...58 Getting Started CG Drives Automation 01 5326 03r5...
Page 74: ...70 EMC and standards CG Drives Automation 01 5326 01r5...
Page 90: ...86 Operation via the Control Panel CG Drives Automation 01 5326 01r5...
Page 218: ...216 CG Drives Automation 01 5326 01r5...
Page 226: ...224 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5326 01r5...
Page 236: ...234 Options CG Drives Automation 01 5326 01r5...
Page 256: ...254 Technical Data CG Drives Automation 01 5326 01r5...
Page 267: ......