Functional Description
CG Drives & Automation, 01-5326-01r5
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active.
Communication information
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active
.
Communication information
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active
.
Communication information
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active
.
Communication information
Motor I
2
Delay time starts counting when the fault is gone. When the
time delay has elapsed, the alarm will be reset if the function
is active
.
Communication information
256
Motor Lost
Default:
Off
Off
0
Off
1–3600
1–3600
1–3600 s
NOTE: Only visible when Motor Lost is selected in
menu [423].
Modbus Instance no/DeviceNet no:
43083
Profibus slot/index
168/242
EtherCAT and CANopen index (hex)
4c0b
Profinet IO index
19467
Fieldbus format
Long, 1=1 s
Modbus format
EInt
257
Locked Rotor
Default:
Off
Off
0
Off
1–3600
1–3600
1–3600 s
Modbus Instance no/DeviceNet no:
43086
Profibus slot/index
168/245
EtherCAT and CANopen index (hex)
4c0e
Profinet IO index
19470
Fieldbus format
Long, 1=1 s
Modbus format
EInt
258
Power Fault
Default:
Off
Off
0
Off
1–3600
1–3600
1–3600 s
Modbus Instance no/DeviceNet no:
43087
Profibus slot/index
168/246
EtherCAT and CANopen index (hex)
4c0f
Profinet IO index
19471
Fieldbus format
Long, 1=1 s
Modbus format
EInt
259
Undervoltage
Default:
Off
Off
0
Off
1–3600
1–3600 1–3600 s
Modbus Instance no/DeviceNet no:
43088
Profibus slot/index
168/247
EtherCAT and CANopen index (hex)
4c10
Profinet IO index
19472
Fieldbus format
Long, 1=1 s
Modbus format
EInt
25A
Motor I
2
t
Default:
Off
Off
0
Off
1–3600
1–3600
1–3600 s
Modbus Instance no/DeviceNet no:
43073
Profibus slot/index
168/232
EtherCAT and CANopen index (hex)
4c01
Profinet IO index
19457
Fieldbus format
Long, 1=1 s
Modbus format
EInt
Summary of Contents for Emotron VFX Series
Page 1: ...Emotron VFX 2 0 AC drive Instruction manual English Valid from software version 4 42...
Page 2: ......
Page 4: ......
Page 10: ...6 CG Drives Automation 01 5326 01r5...
Page 50: ...46 Installation CG Drives Automation 01 5326 01r5...
Page 62: ...58 Getting Started CG Drives Automation 01 5326 03r5...
Page 74: ...70 EMC and standards CG Drives Automation 01 5326 01r5...
Page 90: ...86 Operation via the Control Panel CG Drives Automation 01 5326 01r5...
Page 218: ...216 CG Drives Automation 01 5326 01r5...
Page 226: ...224 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5326 01r5...
Page 236: ...234 Options CG Drives Automation 01 5326 01r5...
Page 256: ...254 Technical Data CG Drives Automation 01 5326 01r5...
Page 267: ......