CG Drives & Automation,01-5326-01r5
Functional Description
141
11.5.7 Preset References [
]
Motor Potentiometer [361]
Sets the properties of the motor potentiometer function. See
the parameter “DigIn1 [521]” for the selection of the motor
potentiometer function.
Communication information
Fig. 110 MotPot function
Preset Ref 1 [362] to Preset Ref 7
[368]
Preset speeds have priority over the analogue inputs. Preset
speeds are activated by the digital inputs. The digital inputs
must be set to the function Pres. Ref 1, Pres. Ref 2 or Pres.
Ref 4.
Depending on the number of digital inputs used, up to 7
preset speeds can be activated per parameter set. Using all
the parameter sets, up to 28 preset speeds are possible.
Communication information
The same settings are valid for the menus:
“[363] Preset Ref 2”, with default 250 rpm
“[364] Preset Ref 3”, with default 500 rpm
“[365] Preset Ref 4”, with default 750 rpm
“[366] Preset Ref 5”, with default 1000 rpm
“[367] Preset Ref 6”, with default 1250 rpm
“[368] Preset Ref 7”, with default 1500 rpm
The selection of the presets is as in Table 35.
361
Motor Pot
Default:
Non Volatile
Volatile
0
After a stop, trip or power down, the AC
drive will start always from zero speed (or
minimum speed, if selected).
Non volatile 1
Non Volatile. After a stop, trip or power
down of the AC drive, the reference value
at the moment of the stop will be
memorized. After a new start command
the output speed will resume to this
saved value.
Modbus Instance no/DeviceNet no:
43131
Profibus slot/index
169/35
EtherCAT and CANopen index (hex)
4c3b
Profinet IO index
19515
Fieldbus format
UInt
Modbus format
UInt
t
t
n
t
Motpot
UP
Motpot
DOWN
362
Preset Ref 1
Default:
Speed, 0 rpm
Dependent
on:
Process Source [321] and Process Unit
[322]
Speed mode
0 - max speed [343]
Torque mode
0 - max torque [351]
Other modes
Min according to menu [324] - max
according to menu [325]
Modbus Instance no/DeviceNet no:
43132–43138
Profibus slot/index
169/36–169/42
EtherCAT and CANopen index (hex)
4c3c - 4c42
Profinet IO index
19516 - 19522
Fieldbus format
Long, 1= 1 rpm, 1
%, 1°C or
0.001 if Process
Value/Process Ref
using a [322] unit
Modbus format
EInt
Table 35
Preset
Ctrl3
Preset
Ctrl2
Preset
Ctrl1
Output Speed
0
0
0
Analogue reference
0
0
1
1)
Preset Ref 1
0
1
1)
0
Preset Ref 2
0
1
1
Preset Ref 3
1
1)
0
0
Preset Ref 4
1
0
1
Preset Ref 5
1
1
0
Preset Ref 6
1
1
1
Preset Ref 7
Summary of Contents for Emotron VFX Series
Page 1: ...Emotron VFX 2 0 AC drive Instruction manual English Valid from software version 4 42...
Page 2: ......
Page 4: ......
Page 10: ...6 CG Drives Automation 01 5326 01r5...
Page 50: ...46 Installation CG Drives Automation 01 5326 01r5...
Page 62: ...58 Getting Started CG Drives Automation 01 5326 03r5...
Page 74: ...70 EMC and standards CG Drives Automation 01 5326 01r5...
Page 90: ...86 Operation via the Control Panel CG Drives Automation 01 5326 01r5...
Page 218: ...216 CG Drives Automation 01 5326 01r5...
Page 226: ...224 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5326 01r5...
Page 236: ...234 Options CG Drives Automation 01 5326 01r5...
Page 256: ...254 Technical Data CG Drives Automation 01 5326 01r5...
Page 267: ......