CG Drives & Automation 01-5326-01r5
Technical Data
247
14.5 Environmental conditions
Table 63
Operation
Parameter
Normal operation
Nominal ambient temperature
0
°
C–40
°
C (32
°
F - 104
°
F) See chapter 14.3 page 243 for different conditions
0
°
C - 45
°
C (32
°
F - 113
°
F) for sizes C69/D69/C2(69)/D2(69)
Atmospheric pressure
86–106 kPa (12.5 - 15.4 PSI)
Relative humidity
according to IEC 60721-3-3
Class 3K4, 5...95% and non condensing
Contamination,
according to IEC 60721-3-3
No electrically conductive dust allowed. Cooling air must be clean and free from corrosive
materials. Chemical gases, class 3C2. Solid particles, class 3S2.
Vibrations
According to IEC 600068-2-6, Sinusodial vibrations:
10<f<57 Hz, 0.075 mm (0.00295 ft)
57<f<150 Hz, 1g (0,035 oz)
Altitude
0–1000 m (0 - 3280 ft)
480V AC drives, with derating 1%/100 m (328 ft) of rated current up to 4000 m (13123 ft)
690V AC drives, with derating 1%/100 m (328 ft) of rated current up to 2000 m (6562) ft
Coated boards required for 2000 - 4000 m(6562 - 13123 ft)
Table 64
Storage
Parameter
Storage condition
Temperature
-20 to +60 °C (-4 to + 140 °F)
Atmospheric pressure
86–106 kPa (12.5 - 15.4 PSI)
Relative humidity
according to IEC 60721-3-1
Class 1K4, max. 95% and non condensing and no formation of ice.
WARNING!
If the device is stored for more than two years, the DC link capacitor of the devices must be reformed
during commissioning.
The reforming procedure is described in manual “Capacitor reforming unit”.
Summary of Contents for Emotron VFX Series
Page 1: ...Emotron VFX 2 0 AC drive Instruction manual English Valid from software version 4 42...
Page 2: ......
Page 4: ......
Page 10: ...6 CG Drives Automation 01 5326 01r5...
Page 50: ...46 Installation CG Drives Automation 01 5326 01r5...
Page 62: ...58 Getting Started CG Drives Automation 01 5326 03r5...
Page 74: ...70 EMC and standards CG Drives Automation 01 5326 01r5...
Page 90: ...86 Operation via the Control Panel CG Drives Automation 01 5326 01r5...
Page 218: ...216 CG Drives Automation 01 5326 01r5...
Page 226: ...224 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5326 01r5...
Page 236: ...234 Options CG Drives Automation 01 5326 01r5...
Page 256: ...254 Technical Data CG Drives Automation 01 5326 01r5...
Page 267: ......