page 14
www.centsys.com
5.2. Endstops
5.3. Guide-rollers and Anti-lift Brackets
Fit opening and closing endstops capable of stopping the gate at rated speed. Refer to
the specifications at the beginning of this manual for the operating speed.
Make H1>H2 to ensure gate will not jump over the endstop.
Guide-rollers must be installed to ensure that the gate is held vertical. For improved
safety, fit additional support posts to prevent the gate from falling over should the
guide-rollers fail.
To prevent unauthorised access, fit anti-lift brackets as shown.
The gap between the anti-lift bracket and the gate must be less than 5mm.
FIGURE 4. FITTING ENDSTOPS
FIGURE 5. FITTING GUIDE-ROLLERS
Opening and closing endstops are mandatory and must be fitted to
prevent death or accidental injury as the operator uses and confirms
these limits during operation.
Endstop
Endstop
Ø16mm
H1
H2
Ensure that the gate cannot be lifted off the motor pinion with the anti-lift
bracket fitted.
GAP <5mm
GAP <5mm
GAP <5mm
GAP <5mm
Additional
support post
Guide-rollers and
Anti-Lift Bracket
Side view of gate and different
Guide-roller options
NEW SITE INSTALLATION PREPARATION
SECTION 5