2.3 B
ENCH
T
EST
– C
OMMUNICATION
C
ONFIGURATION
Connect the Shielded Ethernet Cable:
Connect a shielded Ethernet cable from your Oak Board to the PC.
•
A shielded Ethernet cable will have a metal clip around the RJ-45 connector as shown on the cable on the right in Figure
2.3.1.
•
Centroid recommends using snagless patch cables from StarTech. Use the shortest practical cables.
This information is outlined in Technical Bulletin 251. The latest version can be found
here:
http://www.centroidcnc.com/dealersupport/tech_bulletins/uploads/251.pdf
Note
: An unshielded cable can cause intermittent PC Data receive errors in the software due to electronic noise and
interference.
Length (ft)
Centroid Part Number
6
6144
15
7269
25
6143
Page 13 of 86
Chapter 2 Connecting Components for a Bench Test
Figure 2.3.2
Unshielded Ethernet cable (left) compared to
Shielded Ethernet cable (right)
Figure 2.3.1
Ethernet cable connected to PC
Summary of Contents for 13126
Page 1: ...CENTROID Oak Board Install Manual Last revised 6 3 2021 Page 1 of 86...
Page 10: ...1 3 OVERVIEW Page 10 of 86 Chapter 1 What s included...
Page 22: ...Page 22 of 86 Chapter 3 Software Installation...
Page 41: ...Page 41 of 86 Electrical Cabinet Wiring Figure 5 8 1 Sample VFD Wiring...
Page 42: ...Page 42 of 86 Electrical Cabinet Wiring Figure 5 8 2 Spindle Wiring...
Page 63: ...APPENDIX B TECHNICAL INFORMATION...
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ...APPENDIX C 3RD PARTY DRIVE CABLE INFORMATION Yaskawa Drives Page 83 of 86 Appendices...
Page 84: ...Delta Drives Page 84 of 86 Appendices...