![Casio FX-CG10 User Manual Download Page 571](http://html1.mh-extra.com/html/casio/fx-cg10/fx-cg10_user-manual_2568313571.webp)
ε
-15
Using Advanced Setup
• To specify the countdown start time
1. Move the highlighting to “Timer”.
2. Press
1
(Time) to display a dialog box for specifying the countdown start time.
3. Input a value in seconds from 1 to 10.
4. Press
w
to finalize Trigger Setup and return to the Advanced Setup menu.
• To specify microphone sensitivity
1. Move the highlighting to “Sense” and then press one of the function keys described
below.
To select this level of microphone sensitivity:
Press this key:
Low
1
(Low)
Medium
2
(Middle)
High
3
(High)
2. Press
w
to finalize Trigger Setup and return to the Advanced Setup menu (page
ε
-8).
• To specify the trigger threshold value and trigger edge type
Perform the following steps when “Fast”, “Normal”, or “Clock” is specified as the sampling
mode (page
ε
-11).
1. Move the highlighting to “Threshold”.
2. Press
1
(EDIT) to display a dialog box for specifying the trigger threshold value, which is
value that data needs to attain before sampling starts.
Sensor assigned to CH1 or SONIC by Channel
Setup (page
ε
-9)
Measurement unit supported by assigned sensor
3. Input the value you want, and then press
w
.
4. Move the highlighting to “Edge”.
5. Press one of the function keys described below.
To select this type of edge:
Press this key:
Falling
1
(Fall)
Rising
2
(Rise)
6. Press
w
to finalize Trigger Setup and return to the Advanced Setup menu (page
ε
-8).
Summary of Contents for FX-CG10