EN
19
FUNCTION
DIP SWITCH
MODE
Limit mode
setting
Dip 1/OFF
NC mode(Factory setting)
Dip 1/ON
No Mode
Limit switch direction
setting (J1)
Normal : Short circuit cap simultaneously No1 and No2 of J1 (Factory setting)
If motor system install at left of gate . Please adjust the J1 ,short the cap simultaneously No2 and No3
Infrared
mode set-
ting
Dip 2/OFF
NC mode(Factory setting)
Dip 2/ON
No Mode
CAUTION
If the gate meet obstacles during closing, It will auto stop and auto open. After The gate complete
open to its place, it will auto close again if the obstacle disappear within 2s, if not , it will not auto
close until to the obstacle disappear
Auto close
time
setting
Dip 3&4 all
in OFF
Auto close function disabled (Factory setting)
Dip 3/ON &
4/OFF
10 S
Dip 3&4 all
in ON
30 S
Dip 3/OFF
& 4/ON
60 S
CAUTION
Auto close function activated after gate complete open to its place and stop by limit switch
Auto close
time setting
when
pedestrian
mode
activated
Dip 5&6 all
in OFF
Auto close function disabled(Factory setting)
Dip 5/ON &
6/OFF
5S
Dip 5&6 all
in ON
10S
Dip 5/OFF
& 6/ON
30S
CAUTION
1.When the motor is running, the motor will stop immediately if triggers pedestrian mode
2.After triggering the pedestrian mode to open the gate for 6s, no mater it enter the countdown to close
the gate or stop status, If trigger again, the gate will close the gate immediately.
Condomi-
nium mode
setting
Dip 7 OFF
Condominium mode disabled(factory setting)
Dip 7 ON
Condominium mode activated
CAUTION
When the gate is opening, trigger remote control and the start interface are invalid until the door is
opened.When the gate is closing, trigger remote control and the start interface , the gate will stop
to close and auto open until the opening limit is reached (the remote control and the start interface
are invalid when the gate is opening).
Remote
buttons
mode
Dip 8 OFF
Single button control circularly,First button control gate open,stop, close, second
button use for pedestrian mode(factory setting)
Dip 8 ON
CAUTION
Please choose the remote control mode firstly before remote control code clearning to control
board
Summary of Contents for TANKER C600
Page 5: ...EN 5 Serial Number...
Page 10: ...EN 10 Control board setting Yellow Blue Red...
Page 13: ...EN 13 Connection of the flashing light Connection of infra red photocells...
Page 24: ...FR 24 Num ro de s rie...
Page 29: ...FR 29 Param trage de la carte de contr le Jaune Bleu Rouge...
Page 32: ...FR 32 Connexion des lampes flash Connexion des cellules photo lectriques...
Page 43: ...DE 43 Seriennummer...
Page 48: ...DE 48 Einrichten der Regelkarte Gelb Blau Rot...
Page 51: ...DE 51 Anschluss f r Blitzlampe Photoelektrische Zellenverbindung...
Page 62: ...ES 62 N mero de serie...
Page 67: ...ES 67 Configurando la carta de control Amarillo Azul Rojo...
Page 70: ...ES 70 Conexi n de la l mpara de flash Conexi n de la c lula fotoel ctrica...
Page 81: ...PT 81 N mero de s rie...
Page 86: ...PT 86 Elabora o do gr fico de controlo Amarelo Azul Vermelho...
Page 89: ...PT 89 Liga o da l mpada flash Liga o de c lula fotoel ctrica...
Page 100: ...IT 100 Num ro de s rie...
Page 105: ...IT 105 Impostazione della tabella di controllo Giallo Blu Rosso...
Page 108: ...IT 108 Collegamento lampada flash Collegamento della cellula fotoelettrica...
Page 119: ...NL 119 Serienummer...
Page 124: ...NL 124 Opzetten van de regelkaart Geel Blauw Rood...
Page 127: ...NL 127 Aansluiting voor flitslampen Foto elektrische celverbinding...
Page 138: ...PL 138 Numer seryjny...
Page 143: ...PL 143 Ustawianie schematu kontrolnego ty Niebieski Czerwony...
Page 146: ...PL 146 Pod czenie lampy b yskowej Po czenie z kom rk fotoelektryczn...