83
Regulation of Input Set Point
Set Point No
Regulation
Zero Band
Set Point-1
Maximum Value > Set Point-1
oP-Pre
Set Point-2
Maximum Value > Set Point-2
PrELim
Set Point-3
Set Point-2 > Set Point-3
Final
Set Point-4
Maximum Value > Set Point-4
Fall
Set Point-5
Set Point-3 > Set Point-5
High Limit
Set Point-6
Maximum Value > Set Point-6
Low Limit
Set Point-7
Maximum Value > Set Point-7
Ref 1. When the Set Point value is wrong for the regulation, then “Err” is displayed and the Set
Point value is initialized to ‘0’.
Ref 2. The Regulation has to be observed for the sequential 3 step control and the 1
st
~3
rd
step outputs
are computed as follows.
1
st
Step Output = Final (Set Point 4) – Optional preliminary(Set Point 2)
2
nd
Step Output = Final(Set Point 4) – Preliminary(Set Point 3)
3
rd
Step Output = Final(Set Point 4) – Free fall(Set Point 5)