35
Serial Interface of COM2 Function
F32
Function
Set Baud Rate of COM2
VFD Display
DESCRIPTION
F32 0
600 bps
F32 1
1200 bps
F32 2
2400 bps
F32 3
4800 bps
F32 4
9600 bps
F32 5
19200 bps
F32 6
38400 bps
F32 7
57600 bps
Set Value
(0 ~ 8)
F32 8
115200 bps
F33
Function
Usage of COM2
VFD Display
DESCRIPTION
F33 0
Connection with printer
Set Value
(0 ~ 1)
F33 1
Connection with sub-display or computer
* F29 =0 and F33 = 0 then “Err-Set” displayed. And the print is disconnected.
F34
Function
Output format of COM2
VFD Display
DESCRIPTION
F34 0
22Bytes – CAS Format
F34 1
10Bytes – CAS Format
Set Value
(0 ~ 2)
F34 2
18Bytes – AND Format
F35
Function
Output Mode of COM2
VFD Display
DESCRIPTION
F35 0
No data transmission
F35 1
Transmit data in a state of stable & unstable (Stream Mode)
Set Value
(0 ~ 2)
F35 2
Transmit data only in stable condition
(Transmit 1 time after load in stable condition)
* If it is used as the Print Mode, set F35 = 1
Summary of Contents for NT-580A
Page 1: ...2 ...
Page 12: ...13 2 Measure of Appearance 2 1 Measure of Appearance ...
Page 24: ...25 4 4 Sealing Method Sealing Method of front cal switch ...
Page 53: ...54 External Control I O Circuit ...
Page 58: ...59 Normal Batching Diagram Loss in Weight Batching Diagram ...
Page 59: ...60 UserProgramControlMode NormalBatching ...
Page 61: ...62 UserProgramControlMode Loss in WeightBatching ...
Page 63: ...64 AutomaticProgramControlMode NormalBatching ...
Page 65: ...66 AutomaticProgramControlMode Loss in Weight Batching ...
Page 85: ...86 MEMO ...
Page 86: ...87 ...
Page 87: ...88 ...