61
▣
The external control could be done in favor of user as the above timing chart in the user program
control Mode.
▣
The external input and output signal is like follows.
1.Press the TARE key so that the display value(NET weight) could be 0kg.
2. Zero BAND OUTPUT:
It is ON when GROSS weight is smaller than the ZERO BAND value(S.P1).
3. FIRST OUTPUT(Optional preliminary):
It is ON when the NET weight is more than the set weight(Final(S.P4) – Optional preliminary (S.P2)).
4. SECOND OUTPUT(Preliminary):
It is ON when the NET weight is more than the set weight(Final(S.P4) - Preliminary(S.P2)).
5. Third OUTPUT(Final):
It is ON when the NET weight is more than the set weight(Final(S.P4) – Free fall(S.P5)).
6. HIGH LIMIT OUTPUT:
It is ON when the NET weight is more than the set weight(Final(S.P4) + High limit(S.P6)) after the third
output is ON.
7. LOW LIMIT OUTPUT:
It is ON when the NET weight is smaller than the set weight(Final(S.P4) – Low limit(S.P7)) after the
third output is ON.
8. FINISH OUTPUT:
When the weight is stable, it is ON after the delay time that is specified in F54
It is OFF after the delay time that is specified in F55 or within the Finish Signal OFF Range that is
specified in F56.
Ref. The Discharge Gate control signal could not be supplied in the NT-580A.
-Use the FINISH OUTPUT SIGNAL properly.
Summary of Contents for NT-580A
Page 1: ...2 ...
Page 12: ...13 2 Measure of Appearance 2 1 Measure of Appearance ...
Page 24: ...25 4 4 Sealing Method Sealing Method of front cal switch ...
Page 53: ...54 External Control I O Circuit ...
Page 58: ...59 Normal Batching Diagram Loss in Weight Batching Diagram ...
Page 59: ...60 UserProgramControlMode NormalBatching ...
Page 61: ...62 UserProgramControlMode Loss in WeightBatching ...
Page 63: ...64 AutomaticProgramControlMode NormalBatching ...
Page 65: ...66 AutomaticProgramControlMode Loss in Weight Batching ...
Page 85: ...86 MEMO ...
Page 86: ...87 ...
Page 87: ...88 ...