F55
Function
Timer - Finish Signal Operating Delay Time
VFD Display
DESCRIPTION
F55 00
Do not use
F55 01
0.1 sec
Set Value
(00 ~ 99)
F55 99
9.9 sec
Ref 1. It is used to determine the output time of the finish signal after the batching operation.
Ref 2. If F55 and F56 are set at the same time, Err-Set is displayed and neither are stored.
Set this function to 00(Do not use) in case of using the function(F56) that sets the OFF range of
the finish signal.
F56
Function
Finish Signal OFF Range
VFD Display
DESCRIPTION
F56 00
Do not use
F56 01
Finish signal is off when the weight below one division
Set Value
(00 ~ 99)
F56 99
Finish signal is off when the weight below ninety nine division
Ref 1. If F55 and F56 are set at the same time, Err-Set is shown and neither are stored.
Set this function to 00(Do not use) in case of using the function(F55) that sets the delay time of
the finish signal.