32
F17
Function
Designation of “*”key usage
VFD Display
DESCRIPTION
F17 0
Do not use
F17 1
Print key
Set Value
(0 ~ 2)
F17 2
Hold Key
* Set only one of F29 and F33 to 0 when using the Print Key.
F18
Function
Designation of “Enter”key usage
VFD Display
DESCRIPTION
F18 0
Do not use
F18 1
Total print key
F18 2
Start key in Batching system
Set Value
(0 ~ 3)
F18 3
Stop key in Batching system
F19
Function
Weighing Unit Change
VFD Display
DESCRIPTION
F19 0
Kilogram (kg)
Set Value
(0, 1)
F19 1
Ton (t)
F20
Function
Select of Loadcell Type
VFD Display
DESCRIPTION
F20 0
Compression and tension load cell (0mV ~+40mV)
Set Value
(0, 1)
F20 1
Compression or tension load cell (-20mV ~+20mV)
F21
Function
Initial Zero Range
VFD Display
DESCRIPTION
F21 2
Set of Initial Zero Range within 2% of max weight
Set Value
(2 ~ 20)
F21 10
Set of Initial Zero Range within 10% of max weight
F23
Function
Overload Check
VFD Display
DESCRIPTION
F22 9
Weight value is over 9d of max capacity then ‘Overload’ displayed
Set Value
(9 ~ 99)
F22 99
Weight value is over 99d of max capacity then ‘Overload’ displayed
Summary of Contents for NT-580A
Page 1: ...2 ...
Page 12: ...13 2 Measure of Appearance 2 1 Measure of Appearance ...
Page 24: ...25 4 4 Sealing Method Sealing Method of front cal switch ...
Page 53: ...54 External Control I O Circuit ...
Page 58: ...59 Normal Batching Diagram Loss in Weight Batching Diagram ...
Page 59: ...60 UserProgramControlMode NormalBatching ...
Page 61: ...62 UserProgramControlMode Loss in WeightBatching ...
Page 63: ...64 AutomaticProgramControlMode NormalBatching ...
Page 65: ...66 AutomaticProgramControlMode Loss in Weight Batching ...
Page 85: ...86 MEMO ...
Page 86: ...87 ...
Page 87: ...88 ...