
16
□
G/N Key (Gross/Net key)
▣
Display the gross and net weight by turn.
G. weight lamp on - gross weight.
N. weight lamp on - net weight.
▣
In case the tare weight is registered, the total weight of tare and item is the G. weight
and only the weight of item is N. weight.
▣
To use or To prohibit the Front keys.
(The program is converted by pressing G/N key more than 4 sec.)
□
“ * ” Key
▣
“*” key is used in various ways.
▣
Set the Set Point value for the batching operation.
(The program is converted by pressing * key for more than 2 sec.)
▣
It is used as the function designated in the SET Mode F17.
0. Do not use.
1. PRINT Key.
2. HOLD Key.
□
ENTER Key
▣
ENTER key is used in various ways.
▣
Set the Set Point "CODE" for the batching operation.(00~49)
(The program is converted by pressing the ENTER key for more than 2 sec.)
▣
It is used as the function designated in the SET Mode F18.
0. Do not use.
1. Total print key.
2. Start key for the batching operation.
3. Stop key for the batching operation.
▣
In the CALIBRATION, Test, SET Mode : Store current a condition and exit.
Summary of Contents for NT-580A
Page 1: ...2 ...
Page 12: ...13 2 Measure of Appearance 2 1 Measure of Appearance ...
Page 24: ...25 4 4 Sealing Method Sealing Method of front cal switch ...
Page 53: ...54 External Control I O Circuit ...
Page 58: ...59 Normal Batching Diagram Loss in Weight Batching Diagram ...
Page 59: ...60 UserProgramControlMode NormalBatching ...
Page 61: ...62 UserProgramControlMode Loss in WeightBatching ...
Page 63: ...64 AutomaticProgramControlMode NormalBatching ...
Page 65: ...66 AutomaticProgramControlMode Loss in Weight Batching ...
Page 85: ...86 MEMO ...
Page 86: ...87 ...
Page 87: ...88 ...