4 Nomenclature
18
4.2 Display and Indicators
1) VF Display: The front and rear displays on the LP-2 are dot matrix vacuum fluorescent displays.
They will display all information pertinent to operating the scale.
LP-2 Display Window: Sales
1 2 3
4
5
6
7
16
8
15
14
13
12
11
10
9
WEIGHT lb
UNIT $/ lb
TOTAL PRIC
This is PLU COMMODITY
<REG> Auto PrePack Shift Ride 12:12:00 PM
III
◀
○
◀
ZERO
STABLE
NET
CAPACITY:
E $
0~30 lb x 0.01 lb / 30~60 lb x 0.02 lb, e=d=0.01 lb, 0.02 lb
0~15 kg x 0.005 kg / 15~30 kg x 0.01 kg, e=d=5g, 10g
#
Description
Values
1 Mode indicator
REG, RPK, MGR, ADD, NET
1
, STR
2
,
2 Print Mode indicator
Auto
3 Auto Clearing status indicator
PrePack, Save, (Blank)
4 Speed key Shift status indicator
Shift, (Blank)
5 Override & Discount Status
Ride, DISC, Disc,FSP)
6 Multi-function
indicator
Time, date, scale #, department #,
Alt, Temporary Changes, (Blank)
7 PLU Description line
First non-blank line of PLU commodity
8 Total price heading
TOTAL PRICE and money symbol
9 Total price indicator
7 digits USA: 0.00~9999.99
.10 Unit price heading
UNIT, money and weigh symbols
11 Unit price indicator
6 digits USA: 0.00~999.99
12 Weight indicator
5 digits
13 Weight
heading
WEIGHT
and weigh symbol
14 Negative weight indicator
-, (Blank)
15 Net-Weight
indicator
◀
, (Blank)
16 Stable weight indicator
○
, (Blank)
17 Zero weight indicator
◀
, (Blank)
A Gross Zero indication is reached when the Net-Weight indicator is OFF, the Zero-Weight indicator is
ON, the Stable indicator is ON, and the weight reads 0.00 or 0.000.