6-2
Axxius 800 - Release 2.2
DS1 Controller Card
Overview
Overview
The Quad port DS1 Controller card drives the Axxius 800 Access Integration Platform,
delivering a cost-effective, compact solution enabling wireless service providers to
optimize cell site access facilities, rescue up to 35% of stranded cell sit bandwidth and
deliver additional revenue generating services at dramatically lower costs.
The DS1 Controller card features 4 DS1 ports with integrated CSUs and a built-in 1/0
cross-connect matrix. This provides full, non-blocking connectivity between the
Controller and any of the 8 Service card slots. The Controller connects to the control
panel unit for physical termination of the on-board DS1 circuits, as well as access to
the RS-232 and Ethernet management interfaces.
The DS1 Controller card manages all the other Axxius Service cards providing the
physical, electrical and logical connections to deliver a complete wireless cell site
solution.
The DS1 Controller card has several local and remote management options available.
Front-panel LEDs quickly communicate alarm, system and line status. The card can be
configured and managed locally through the RS-232 or Ethernet management
connections on the Control Panel using a Command Line Interface (CLI).
A number of remote management options are available to reduce truck roll costs for
most maintenance and troubleshooting activities. The in-band DS0 management
channel on the Controller delivers 64 Kbps remote access to the Axxius without
incurring additional facility costs. Alternatively, a separate Ethernet facility can be
deployed to support out-of-band SNMP network management and the Controller can
also be accessed through the V.34 dial-in modem connection from the Order Wire
POTS with Modem Service card.
NOTE:
Removing an active Controller is not recommended, use the
switch controller command to change the Active Controller to Standby and
then remove the Controller card.
Summary of Contents for Network Device Axxius 800
Page 1: ...Axxius 800 USER MANUAL Part Number 770 0104 AG Product Release 2 2 May 2004 ...
Page 32: ...xxxii Axxius 800 Release 2 2 Table of Contents ...
Page 50: ...1 18 Axxius 800 Release 2 2 Base Platform ACO ...
Page 101: ...CHAPTER CLI Commands In this Chapter n Command Line Interface Help n CLI Commands ...
Page 392: ...8 8 Axxius 800 Release 2 2 FXO Voice Card Channel Associated Signaling CAS Conversions ...
Page 430: ...12 8 Axxius 800 Release 2 2 Power Supply Installing Replacing a Power Supply ...
Page 472: ...15 20 Axxius 800 Release 2 2 Terminal Server Router Card LEDs ...
Page 500: ...18 12 Axxius 800 Release 2 2 Maintenance Hot Swap Service Card ...
Page 532: ...C 22 Axxius 800 Release 2 2 Loopback Tests V 35 V 54 Loop ...
Page 552: ...Glossary 20 Axxius 800 Release 2 2 Glossary ...