Axxius 800 - Release 2.2
10-11
OCU-DP Card
Alarms
Alarms
The OCU-DP cards and supporting Controller Software will support the following
alarms:
Alarm/
Event
Severity
Category
Description
Clear Mechanism
(alarms only)
Card
Detect
Information
Equipment
OCU-DP card inserted
Card
Removed
Information
Equipment
OCU-DP card removed
Out of
Service
(OOS)
Major
Facility
Network sending Out-of-
Service code (OOS) or
card has LOS.
Correct with Network or
replace or deprovision the
card.
Los of
Signal
(LOS)
Major
Facility
No signal at customer link.
Correct with Customer
data path, replace the card,
or reconnect the drop.
Los of
Frame
(LOF)
Major
Facility
Framing patter not
detected at customer link.
Correct with Customer
data path, replace the card,
or reconnect the drop.
Bipolar
Violation
(BPV)
Minor
Facility
Excessive violations on
customer interface.
Correct with the incoming
signal, or deprovision card.
Summary of Contents for Network Device Axxius 800
Page 1: ...Axxius 800 USER MANUAL Part Number 770 0104 AG Product Release 2 2 May 2004 ...
Page 32: ...xxxii Axxius 800 Release 2 2 Table of Contents ...
Page 50: ...1 18 Axxius 800 Release 2 2 Base Platform ACO ...
Page 101: ...CHAPTER CLI Commands In this Chapter n Command Line Interface Help n CLI Commands ...
Page 392: ...8 8 Axxius 800 Release 2 2 FXO Voice Card Channel Associated Signaling CAS Conversions ...
Page 430: ...12 8 Axxius 800 Release 2 2 Power Supply Installing Replacing a Power Supply ...
Page 472: ...15 20 Axxius 800 Release 2 2 Terminal Server Router Card LEDs ...
Page 500: ...18 12 Axxius 800 Release 2 2 Maintenance Hot Swap Service Card ...
Page 532: ...C 22 Axxius 800 Release 2 2 Loopback Tests V 35 V 54 Loop ...
Page 552: ...Glossary 20 Axxius 800 Release 2 2 Glossary ...