background image

CUSTOMER

SUPPORT

INFORMATION

Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA  15055-1018
Web site: www.blackbox.com • E-mail: [email protected]

 

Multiport Analog VoIP Router

 

Important

 

This is a Class A device and is intended for use in a light industrial environment. It is not intended nor 
approved for use in an industrial or residential environment.

 

Approval

 

Models that are equipped with FXO interfaces have been approved for connection to the public telecom-
munication network.

 

JUNE 2007

VOE231
VOE232
VOE233
VOE234
VOE235
VOE236

Summary of Contents for VOE231

Page 1: ...nce PA 15055 1018 Web site www blackbox com E mail info blackbox com Multiport Analog VoIP Router Important This is a Class A device and is intended for use in a light industrial environment It is not intended nor approved for use in an industrial or residential environment Approval Models that are equipped with FXO interfaces have been approved for connection to the public telecom munication netw...

Page 2: ... by a circuit breaker For AC powered units ensure that the power cable used meets all applicable standards for the country in which it is to be installed and that it is connected to a wall outlet which has earth ground Hazardous network voltages are present in WAN ports regardless of whether power to the VOE230 is ON or OFF To avoid electric shock use caution when near WAN ports when detaching the...

Page 3: ...r supply and cable 2 When the Power LED stops blinking and remains lit the VOE230 is ready to configure The terminal block header to which the wires are secured pro vides the disconnect for the VOE230 Take proper measures to ensure that it is not permanently fastened to the receptacle mounted on the chassis CAUTION ...

Page 4: ...0 0 is configured as DHCP client Figure 1 Connecting the VOE230 to your PC through a hub or switch Figure 2 Connecting the VOE230 directly to your PC Option 2 Connect directly to a PC LAN interface ETH0 1 is configured as DHCP server see Figure 2 1 Configure your PC as a DHCP client Note The procedures below are for Microsoft Windows For another operating system refer to the operating instruction ...

Page 5: ...s window Figure 4 Displaying the Internet Properties TCP IP Properties window 3 Double click on Local Area Connection and click on Properties to open the Internet Protocol TCP IP Properties window see Figure 4 4 Select Obtain an IP address automatically and Obtain DNS server address automatically options 5 Click OK to save changes and close the properties windows ...

Page 6: ...ed ETH0 1 directly to the Ethernet port on your PC see figure 2 on page 4 Option 3 Connect the VOE230 console port to your PC If your PC has an RS 232 serial COM port you may use it to connect the VOE230 Console port Refer to the VOE230 Getting Started Guide located on the CD ROM shipped with your VOE230 for the procedure ...

Page 7: ...e CD to your PC 3 At your PC double click the VOEDiscovery exe file name to activate the tool The VOE Discovery Tool window will display the IP Address MAC Address Device Type model number and Build software release of your VOE230 If your VOE230 does not appear Make sure the VOE230 and your PC are on the same routed subnet Make sure any firewall programs on your PC are disabled ...

Page 8: ...y display ing its IP address as the command line prompt 4 After you log in your VOE230 will be running in operator execution mode indicated by character in the command line prompt To enter configura tion mode use the commands enable and configure 10 10 22 50 enable 10 10 22 50 configure 10 10 22 50 cfg You may now start to configure the VOE230 from scratch using the CLI com mands but we recommend ...

Page 9: ...iguration file template In this example we assume an TFTP server resides on the host with the IP address 10 10 1 11 and the configuration file named VOE cfg resides in the root directory of the TFTP server 10 10 22 50 if ip eth0 copy tftp 10 10 1 11 VOE cfg star tup config Download 100 10 10 22 50 if ip eth0 After you reboot the VOE230 the new startup configuration will become active 10 10 22 50 i...

Page 10: ...on the CD ROM shipped with your VOE230 device and available online at www blackbox com manuals For detailed information about Installing configuring operating and troubleshooting Warranty trademark compliance The CD ROM also includes many freeware and shareware tools including TFTP servers and Telnet clients ...

Page 11: ...nterface Ethernet 0 ETH 0 0 DHCP client DHCP client LAN interface Ethernet 1 ETH 0 1 The VOE230 factory default configuration includes a DHCP server running on the ETH 0 1 All Ethernet ports are pre configured and active 192 168 1 1 255 255 255 0 DHCP server address range 192 168 1 10 192 168 1 19 255 255 255 0 ...

Page 12: ...ompliance Information B 1 Compliance EMC FCC Part 15 Class A EN55022 Class A EN55024 Safety UL60950 1 CSA C22 2 No 60950 1 IEC 60950 1 EN60950 1 AS NZS 60950 1 PSTN Regulatory Compliance FCC Part 68 CS 03 TBR 21 AS ACIF S002 AS ACIF S003 ...

Page 13: ...lies with Part 68 of the FCC rules and the requirements adopted by ACTA On the bottom side of this equipment is a label that contains among other information a product identifier in the format US AAEQ TXXXX If requested this number must be provided to the tele phone company The method used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Pa...

Page 14: ...ac tion Before installing the equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection In some cases the company s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly telephone exten...

Page 15: ... and the Committee for the Harmonization of the Legal Regulations of the Member States concerning radio equipment and telecommunications terminal equipment and the mutual recognition of their con formity B 6 Approval Models that are equipped with FXO ports have been approved for connection to the public telecommunication network The safety advice in the documentation accompanying the products shal...

Page 16: ... Copyright 2007 Black Box Corporation All rights reserved 1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 ...