Axxius 800 - Release 2.2
5-79
CLI Commands
set
id
Set the DS1 circuit identification name. This is the same as dsx1Circuit
Identifier from DS1 MIB transmission vendor’s identification. String
text must be enclosed in quotes
.
Example: set {ds1-addr} id {"id-name"}
{id-name} = transmission vendor’s ID, up to 30 characters, in quotes.
lbo
Set the Line Build Out (LBO) to one of the following: Note: this
options is not applicable on a DS1 within a DS3.
1
DSX-1 equalization for 0-133 feet (equivalent to CSU
attenuation for LBO of 0dB)
2
DSX-1 equalization for 133-266 feet
3
DSX-1 equalization for 266-399 feet
4
DSX-1 equalization for 399-533 feet
5
DSX-1 equalization for 533-655 feet
6
CSU attenuation for LBO of -7.5dB
7
CSU attenuation for LBO of -15dB
8
CSU attenuation for LBO of -22.5dB
line
Turn a line loopback to the DS1 interface on or off. If the line command
is not used, the default for line loopback is loopdown.
loopdown
Disable the line loopback
loopup
Enable a DS1 line loopback toward the DS1 drop
linecode
Set the DS1 interface line coding to one of the following. If the linecode
command is not used, the default for linecode is B8ZS.
Note: this options is not applicable on a DS1 within a DS3.
ami
Alternate Mark Inversion line coding
b8zs
Binary 8 Zero Substitution line coding.
loopdetect
Enable detection of CSU loop code (10000 - loopup; 100 - loopdown)
on
Enable detection
off
Disable detection
payload
Apply a payload loopback to the DS1 interface. If the payload
command is not used, the default for payload loopback is loopdown.
loopdown
Disable the payload loopback
loopup
Enable the payload loopback
Summary of Contents for Network Device Axxius 800
Page 1: ...Axxius 800 USER MANUAL Part Number 770 0104 AG Product Release 2 2 May 2004 ...
Page 32: ...xxxii Axxius 800 Release 2 2 Table of Contents ...
Page 50: ...1 18 Axxius 800 Release 2 2 Base Platform ACO ...
Page 101: ...CHAPTER CLI Commands In this Chapter n Command Line Interface Help n CLI Commands ...
Page 392: ...8 8 Axxius 800 Release 2 2 FXO Voice Card Channel Associated Signaling CAS Conversions ...
Page 430: ...12 8 Axxius 800 Release 2 2 Power Supply Installing Replacing a Power Supply ...
Page 472: ...15 20 Axxius 800 Release 2 2 Terminal Server Router Card LEDs ...
Page 500: ...18 12 Axxius 800 Release 2 2 Maintenance Hot Swap Service Card ...
Page 532: ...C 22 Axxius 800 Release 2 2 Loopback Tests V 35 V 54 Loop ...
Page 552: ...Glossary 20 Axxius 800 Release 2 2 Glossary ...