17
During the opening/closing manoeuvre check for correct operation and activate the
emergency stop button in case of danger.
During blackouts the gate can be released and manually manoeuvred using the
supplied release key (see manual release pag. 7).
Periodically check the moving parts for wear and tear and grease if required using
lubricants which maintain their friction levels unaltered throughout time and are
suitable for temperatures of
-20 to +70°C
. In case of failure or operational anomalies
switch off the power at the mains do not attempt to repair the appliance yourself.
Periodically check the correct operation of all safety devices (photoelectric cells etc.).
Eventual repair work must be carried out by specialised personnel using original
spare parts. The appliance is not suitable for continuous operation and must be
adjusted according to the model (see technical data on page 52).
The minimum controls which may be installed are OPEN-STOP-CLOSE, these
controls must be installed in a location not accessible to children and outside the
opening range of the gate.
Before starting the installation of the system check that the structure which is
to be automated is in good working order and respects the local standards and
regulations in force.
To this end make sure that the gate is sufficiently rigid (if necessary reinforce the
structure) and that it pivots easily.
You are advised to grease all the moving parts using lubricants which maintain
unaltered friction characteristics over a period of time and are suitable for tem-
peratures of
-20 to +70°C
.
s #HECKTHESAFETYMEASURESBETWEENTHElXEDANDMOVINGPARTS
- a minimum space of
30 mm
must always be left along the entire distance
between the gate and the support column measured throughout the entire open-
ing angle of the gate.
- make sure that the space between the bottom of the gate and the pavement
never exceeds
30 mm
throughout the entire opening angle of the gate.
s 4HESURFACEOFTHEGATEMUSTNOTFEATUREOPENINGSWHICHALLOWAPERSONSHAND
or foot to pass through.
s #HECKTHEEXACTPOSITIONINGOFTHEPIVOTSANDTHEIRGOODWORKINGORDERTHE
upper and lower hinges/pivots must be aligned on the same axis).
s 7ORKOUTTHERUNOFTHECABLESACCORDINGTOTHECOMMANDANDCONTROLDEVICES
fitted and make sure the system conforms to the local standard and regulations
in force (see installation example fig. 1 pag. 2).
s #HECKTHATTHEAPPLIANCEISSUITABLEFORTHESIZEWEIGHTANDDUTYCYCLEOFTHE
gate to which it is to be applied (see duty cycle on page 52)
FITTING THE UNIT
- Choose the ideal position for the foundation case according to the opening angle
(
90°
-
110°-180°
fig. 5) and the position of the gate pivot.
- Place a mechanical travel buffer in the closing direction (detail "
1
", fig. 5).
- Dig the foundation hole "
A
" (fig. 6) sufficiently large to house the foundation case
and run a drain channel up to the hole "
B
".
- Run the channelling for the cables up to the hole "
C
".
- Insert the six round headed screws "
E
" into the holes on the bottom of the case
and fasten down using the supplied nuts and washers.
- Place the foundation case in the hole with the pin perpendicular to the upper
gate pivot "
D
", cover the case in concrete and check that it is in square and that
the upper edge protrudes by at least
3 mm
from the ground.
- Remove the nuts and washers used to fasten down the round headed bolts in
the embedding case.
- Insert the motor reduction unit and fasten down using four of the six threaded
bolts "
E
" located underneath the motor.
- Weld the upper bar "
F
" complete with release mechanism to the gate remembering
that the pin "
G
" of the lever must be in line with the upper gate pivot "
D
".
- At this point proceed according to your model as follows:
IMPORTANT SAFETY INSTRUCTIONS
These instructions are aimed at professionally qualified "
installers of electrical
equipment
" and must respect the local standards and regulations in force. All
materials used must be approved and must suit the environment in which the
installation is situated.
s !LLMAINTENANCEOPERATIONSMUSTBECARRIEDOUTBYPROFESSIONALLYQUALIlEDTECHNI
-
cians. Before carrying out any cleaning or maintenance operations make sure
the power is disconnected at the mains.
s 4HISAPPLIANCEMUSTBEUSEDEXCLUSIVELYFORTHEPURPOSEFORWHICHITHASBEEN
made. "i.e.
for the automation of hinged gates
" with one or two gate leaves,
max.
length 3 m
, max. weight
350 kg
.
s 4HEUNITMAYBElTTEDBOTHTOTHERIGHTANDTOTHELEFTOFTHEPASSAGEWAY
This product and all its relative components has been designed and manufac-
tured by Cardin Elettronica who have verified that the product conforms in every
aspect to the safety standards in force. Any non authorised modifications are
to be considered improper dangerous and the complete responsibility of the
installer.
Caution!
a mechanical stop buffer must be installed in closing position
(pos. 1 fig. 5).
It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main road
to eliminate possible traffic disruptions.
2) The motor must be installed on the inside of the property at a height between
1,5
and
1,8 m
and not on the public side of the gate. The gates must not open
onto a public area.
3) The gate operator is designed for use on gates through which vehicles are pass-
ing. Pedestrians should use a separate entrance.
4) The gate must be in full view when it is operating therefore controls must be
situated in a position where the operator can see the gate at all times.
5) At least two warning signs (similar to the example on the right) should be placed,
where they can be easily seen by the public, in the area of the
system of automatic operation. One inside the property and one
on the public side of the installation. These signs must be indelible
and not hidden by any objects (such as tree branches, decorative
fencing etc.).
6) Make sure that the end-user is aware that children and/or pets
must not be allowed to play within the area of a gate installation.
If possible include this in the warning signs.
7) Whenever a fully open gate leaf comes within
b
500 mm
of a fixed structure the
space must be protected by an anticrush buffer (fig. 1, detail 11).
8) If you have any questions about the safety of the gate operating system, do not
install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
800/HL2524ESB
Irreversible geared motor, maximum opening
110°
.
806/HLCF1
Embedding case in zinc plated steel with cataphoresis finishing
and a transmission lever for
110°
.
806/HLCF1Z
Embedding case in zinc plated steel with transmission lever for
110°
.
800/HL1824ESB
Irreversible geared motor, gate opening
118°-360°
.
806/HLCF18
Embedding case in zinc-plated steel with cataphoresis finishing
and accessories for gate opening
110°-360°
.
806/HLCF18Z
Embedding case in zinc-plated steel with accessories for gate
opening
110°-360°
.
806/HLCA140
Kit of lever accessories for a
140°
opening angle.
s 3INGLEPIECEGEAREDREDUCTIONUNITWITHANINCORPORATEDENCODER
s $IRECTCURRENTDRIVEMOTORMAX
28 Vdc
.
s 0ERMANENTLYLUBRICATEDIRREVERSIBLEGEAREDMOTORMOUNTEDINACASTALUMINIUM
case.
s 2UBBERSEALINGGASKET
s KEYOPERATEDMANUALRELEASEMECHANISM
s %MBEDDINGCASEINHOTROLLEDZINCPLATEDSTEEL
- release unit housing in pressed aluminium
s 4RANSMISSIONLEVERSINZINCPLATEDSTEEL
- gate fastening bracket in zinc-plated steel.
ACCESSORIES
980/XLSE11C
- Electric locking device
12 Vac/dc
AUTOMATIC OPENING
KEEP CLEAR
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
WARNING
IMPORTANT REMARKS
IMPORTANT REMARKS
IMPORTANT REMARKS
TO REDUCE THE RISK OF SEVERE INJURY OR DEATH READ THE FOLLOWING REMARKS
CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO
ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
. NOT READING THESE IMPORTANT
INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM.