Troubleshooting
Fault Code
and Message
Fault
Cause
Correction
Damaged harness
Do a check of the harnesses and
connections, repair or replace as
necessary
Internal hub problem
Contact CapstanAG to repair or
replace the hub.
Fault 89:
Section 6 Valve
Open Circuit
Section 6 Valve
Open Circuit
Servo valve failure
Repair or replace the servo valve
Damaged harness
Do a check of the harnesses and
connections, repair or replace as
necessary
Internal hub problem
Contact CapstanAG to repair or
replace the hub.
Fault 90:
Section 7 Valve
Open Circuit
Section 7 Valve
Open Circuit
Servo valve failure
Repair or replace the servo valve
Damaged harness
Do a check of the harnesses and
connections, repair or replace as
necessary
Internal hub problem
Contact CapstanAG to repair or
replace the hub.
Fault 91:
Section 8 Valve
Open Circuit
Section 8 Valve
Open Circuit
Servo valve failure
Repair or replace the servo valve
Fault 92:
Section 1 Low
Pressure
Section 1 Low
Pressure
If you are using sectional
pressure sensors, this
means the section is below
the minimum voltage for the
pressure sensor.
Do a check of the pressure
sensor, harnesses, and
connections, repair or replace as
necessary.
Fault 93:
Section 2 Low
Pressure
Section 2 Low
Pressure
If you are using sectional
pressure sensors, this
means the section is below
the minimum voltage for the
pressure sensor.
Do a check of the pressure
sensor, harnesses, and
connections, repair or replace as
necessary.
Fault 94:
Section 3 Low
Pressure
Section 3 Low
Pressure
If you are using sectional
pressure sensors, this
means the section is below
the minimum voltage for the
pressure sensor.
Do a check of the pressure
sensor, harnesses, and
connections, repair or replace as
necessary.
Fault 95:
Section 4 Low
Pressure
Section 4 Low
Pressure
If you are using sectional
pressure sensors, this
means the section is below
the minimum voltage for the
pressure sensor.
Do a check of the pressure
sensor, harnesses, and
connections, repair or replace as
necessary.
Fault 96:
Section 5 Low
Pressure
Section 5 Low
Pressure
If you are using sectional
pressure sensors, this
means the section is below
the minimum voltage for the
pressure sensor.
Do a check of the pressure
sensor, harnesses, and
connections, repair or replace as
necessary.
©
2021 Capstan Ag Systems, Inc.
96
PinPoint
™
III ENVELOP
Summary of Contents for PinPoint III ENVELOP
Page 6: ......
Page 65: ...TM Operation 2021 Capstan Ag Systems Inc 65 PinPoint III ENVELOP...
Page 66: ...TM Operation Nozzle Spacing 50 cm 2021 Capstan Ag Systems Inc 66 PinPoint III ENVELOP...
Page 67: ...TM Operation 2021 Capstan Ag Systems Inc 67 PinPoint III ENVELOP...
Page 69: ...TM Operation 2021 Capstan Ag Systems Inc 69 PinPoint III ENVELOP...
Page 71: ...TM Operation 2021 Capstan Ag Systems Inc 71 PinPoint III ENVELOP...
Page 72: ...TM Operation Nozzle Spacing 20 in 2021 Capstan Ag Systems Inc 72 PinPoint III ENVELOP...
Page 73: ...TM Operation 2021 Capstan Ag Systems Inc 73 PinPoint III ENVELOP...
Page 75: ...TM Operation 2021 Capstan Ag Systems Inc 75 PinPoint III ENVELOP...
Page 76: ...TM Operation 2021 Capstan Ag Systems Inc 76 PinPoint III ENVELOP...
Page 84: ...TM Maintenance 2021 Capstan Ag Systems Inc 84 PinPoint III ENVELOP...
Page 116: ...TM Troubleshooting 2021 Capstan Ag Systems Inc 116 PinPoint III ENVELOP...
Page 122: ...TM Schematics System Layout Figure 42 2021 Capstan Ag Systems Inc 122 PinPoint III ENVELOP...
Page 124: ...TM Schematics 2021 Capstan Ag Systems Inc 124 PinPoint III ENVELOP...
Page 127: ......