Self-diagnostic Display
9-16
T
roub
le
sh
oot
in
g
9
# 0408
Cause 1
The transfer of data has failed because the USB memory media device was
pulled out during the transfer.
Remedy
Check that the USB memory media device is properly inserted, and then try the
transfer again.
Cause 2
An error occurred while data, such as image data, was being transferred to the
USB memory media device.
Remedy
Check the status of the USB memory media device, or make sure that the
device is formatted with a file system supported by the machine (FAT16 or
FAT32), and then try again.
# 0703
Cause
The memory for image data is full when sending color documents.
Remedy 1 Wait for a few moments and try again after other send jobs are complete.
Remedy 2 Delete documents stored in memory. If the machine still does not operate
normally, turn the main power OFF and then back ON.
# 0705
Cause
The send operation was interrupted because the size of the image data is larger
than that specified in <Maximum TX Data Size> in E-mail/I-Fax Settings.
Remedy 1 Change the setting for <Maximum TX Data Size> in E-mail/I-Fax Settings. (See
Chapter 4, “Setting the Send Function,” in the
System Settings Guide
.)
Remedy 2 Select a lower resolution. (See “Specifying the Color Mode and Resolution,” on
Remedy 3 If you are using I-fax, decrease the number of pages containing images that you
are sending each time, so that you do not exceed the data size limit specified in
<Maximum TX Data Size>.
Remedy 4 Set Divide into Pages to ‘On’ on the File Format screen. (See “Specifying the
# 0751
Cause 1
The file server is not functioning.
Remedy
Check that the file server is operating properly.
Summary of Contents for imageRUNNER 2545i
Page 175: ...LDAP Server 4 68 Specifying Destinations Easily and Quickly 4 ...
Page 257: ...Reception Related Items 7 44 Customizing the Machine s Settings 7 ...
Page 299: ...Self diagnostic Display 9 24 Troubleshooting 9 ...
Page 319: ...Index 10 20 Appendix 10 U User s Data List 8 8 ...
Page 320: ...Index 10 21 10 ...