4
4
4-52
4-52
Parts Replacement and Cleaning > PCB > Removing the Shutter Motor (M8) > Replacement Procedure
Parts Replacement and Cleaning > PCB > Removing the Shutter Motor (M8) > Replacement Procedure
- 2 connectors
x2
4) Remove the gear.
-1 claw
CAUTION:
When reinstalling the gear, put the triangle marks of the right and left rack together.
x1
F-4-117
F-4-118
5) Remove the rack (right).
- 2 claws
6) Remove the shutter motor.
- 2 screws
F-4-119
F-4-120
Summary of Contents for imageRUNNER 2545
Page 15: ...1 1 Product Overview Product Overview Product Lineup Feature Specifications Name of Parts...
Page 105: ...3 3 Periodical Service Periodical Service Consumable Parts and Cleaning Parts...
Page 177: ...5 5 Adjustment Adjustment Outline Adjustment when replacing parts Image position adjustment...
Page 195: ...7 7 Error Code Overview Error Code Jam Code Alarm Code...
Page 205: ...7 7 7 11 7 11...
Page 211: ...8 8 Service Mode Outline Details of Service Mode...
Page 354: ...Service Tools General Circuit Diagram Appendix...