4
4
4-41
4-41
Parts Replacement and Cleaning > Consumable Parts Requiring Periodic Replacement > Removing the Cassette Feed Roller
Parts Replacement and Cleaning > Consumable Parts Requiring Periodic Replacement > Removing the Cassette Feed Roller
Removing the Fixing Unit
1) Open the right cover
2) Remove the fixing unit.
- 2 screws
x2
MEMO:
Hold the fixing unit at the position shown below.
F-4-93
F-4-92
Removing the Cassette Pickup Roller
1) Draw out the cassette from the main unit.
2) Open the right cover.
3) Remove the leaf spring with your fingers.
4) Remove the cassette pickup roller.
- 1 claw
x1
Removing the Cassette Feed Roller
1) Draw out the cassette from the main unit.
2) Open the right cover.
3) Remove the cassette transfer roller.
- 1 claw
x1
F-4-94
F-4-95
Summary of Contents for imageRUNNER 2545
Page 15: ...1 1 Product Overview Product Overview Product Lineup Feature Specifications Name of Parts...
Page 105: ...3 3 Periodical Service Periodical Service Consumable Parts and Cleaning Parts...
Page 177: ...5 5 Adjustment Adjustment Outline Adjustment when replacing parts Image position adjustment...
Page 195: ...7 7 Error Code Overview Error Code Jam Code Alarm Code...
Page 205: ...7 7 7 11 7 11...
Page 211: ...8 8 Service Mode Outline Details of Service Mode...
Page 354: ...Service Tools General Circuit Diagram Appendix...