6
6
6-7
6-7
■
Abnormal Noise During Multi-Feed Peration
[Occurrence area]
Gear of right cover unit
[Cause]
When the right cover unit is closed, the belt cannot enter the clearance groove depending on
the lower belt securing position and therefore the belt is Z-folded. As a result, the right cover
unit is pushed out and consequently the gear on the right cover unit side meshes with the
gear on the host machine side loosely, generating abnormal noise.
[Occurrence condition]
When the belt of the right cover unit is reinstalled
[Remedy]
Secure the belt to the right cover unit in such a manner that it does not turn along with the
screw (i.e., it is secured horizontally or it faces slightly down).
Escape hole
F-6-4