8
8
8-13
8-13
●
SSSW-SW35
List of Functions
Bit
Function
1
0
0
e-RDS function ON/OFF
Yes
No
1
Call button function ON/OFF
Yes
No
2
ScanToMeia function enable/disable
enable
disable
3
MediaPrint function enable/disable
enable
disable
4
IC card authentication management function ON/OFF Yes
No
5
not used
-
-
6
not used
-
-
7
not used
-
-
Detailed Discussions of Bit 0
Select whether to set the e-RDS function.
When "1" is selected, the function is set.
When "0" is selected, the function is not set.
Detailed Discussions of Bit 1
Select whether to set the call button function.
When "1" is selected, the function is set.
When "0" is selected, the function is not set.
Detailed Discussions of Bit 2
Select whether to enable or disable the ScanToMeia function.
When "1" is selected, the function is enabled.
When "0" is selected, the function is disabled.
Detailed Discussions of Bit 3
Select whether to enable the MediaPrint function.
When "1" is selected, the function is enabled.
When "0" is selected, the function is disabled.
Detailed Discussions of Bit 4
Select whether to set the IC card authentication function.
When "1" is selected, the function is set.
When "0" is selected, the function is not set.
T-8-26
#MENU
■
Menu Switch Composition
No.
Function
Range of settings
005
NL equalizer
1: ON, 0: OFF
006
Telephone line monitor 0: DIAL, 1: SERVICEMAN [1], 2: SERVICEMAN [2], 3: OFF
007
Transmission level (ATT) From 0 to 15 (ex: 15= -15 dBm)
008
V.34 modulation speed
upper limit
0: 3429, 1: 3200, 2: 3000, 3: 2800, 4: 2743, 5: 2400
009
V34 data speed upper
limit
0: 33.6kbs, 1: 31.2kbs, 2: 28.8kbs, 3: 26.4kbs, 4: 24.0kbs
5: 21.6kbs, 6: 19.2kbs, 7: 16.8kbs, 8: 14.4kbs, 9: 12.0kbs
10: 9.6kbs, 11: 7.2kbs, 12: 4.8kbs, 13: 2.4kbs
010
Frequency of pseudoring
signal
0: 50Hz, 1: 25Hz, 2: 17Hz
■
Deatails
●
<005: NL equalizer>
Use it to enable-disable the NL equalizer.
If errors occur often during communication because of the condition of the line, enable (ON)
the NL equalizer.
MEMO:
Any of the following error codes may be indicated at time of transmission because of
the line condition:
##100, ##101, ##102, ##104, ##201, ##281, ##282, ##283, ##750, ##755, ##765,
##774, ##779, ##784, ##789
Any of the following error codes may be indicated at time of transmission because of
the line condition:
##103, ##107, ##114, ##201, ##790, ##793
●
<006: Telephone line monitor>
Use it to s the telephone line monitor function:
DIAL: generate the monitor sound of the telephone line using the speaker from the start of
transmission to DIS.
SERVICEMAN [1]: generate the monitor sound of the telephone line using the speaker
from the start of communication to the end of it.
SERVICEMAN [2]: generate the monitor sound of the telephone line2 (Option).
OFF: do not generate the monitor sound of the telephone line using the speaker.
T-8-27
Summary of Contents for imageRUNNER 2545
Page 15: ...1 1 Product Overview Product Overview Product Lineup Feature Specifications Name of Parts...
Page 105: ...3 3 Periodical Service Periodical Service Consumable Parts and Cleaning Parts...
Page 177: ...5 5 Adjustment Adjustment Outline Adjustment when replacing parts Image position adjustment...
Page 195: ...7 7 Error Code Overview Error Code Jam Code Alarm Code...
Page 205: ...7 7 7 11 7 11...
Page 211: ...8 8 Service Mode Outline Details of Service Mode...
Page 354: ...Service Tools General Circuit Diagram Appendix...