4
4
4-30
4-30
Parts Replacement and Cleaning > Main Units/Parts > Removing the CCD Unit
Parts Replacement and Cleaning > Main Units/Parts > Removing the CCD Unit
3)Remove the bottle ring.
F-4-58
Removing the CCD Unit
1) When replacing with a new CCD unit, enter the following service mode to output a service
data list.
REPORT> REPORT OUTPUT> SERVICE DATA LIST
2) Open the platen cover (ADF/platen board cover).
3) Remove the reader right cover.(
“Removing the Reader Right Cover”(page 4-20)..)
4) Remove the right glass retainer.
5) Remove the platen glass.(
“Removing the Platen Glass”(page 4-20)..
)
6Move the belt in the direction of the arrow and move the CCD unit to the position of the
groove in the frame.
7) Remove the shaft retaining blade.
• 1 screw
x1
F-4-59
F-4-60