8
8
8-8
8-8
●
SSSW-SW06
List of Functions
Bit
Function
1
0
0
not used
-
-
1
not used
-
-
2
not used
-
-
3
FAX stamp display setting
Displayed
Not displayed
4
original read width
LTR
A4
5
not used
-
-
6
not used
-
-
7
not used
-
-
Detailed Discussions of Bit 3
Select whether to display the stamp menu in the user menu after installation of the optional
stamp unit.
Detailed Discussions of Bit 4
Use it to select a read width for originals.
If ‘LTR’ is selected, the machine will read LTR originals at LTR width (214mm).
●
SSSW-SW012
List of Functions
Bit
Function
1
0
0
1-page time-out length for transmission
1
0
1
not used
-
-
2
1-page time-out length for transmission (HT
transmission)
1
0
3
not used
-
-
4
1-page time-out length for reception
1
0
5
not used
-
-
6
not used
-
-
7
page timer setting by transmission/reception
set
do not set
The machine will stop the ongoing communication if the transmission/reception of a single
original page takes 32 min or more. To use the timer for a purpose other than this function,
refer to the tables that follow, and select an appropriate time length.
When 'do not enable' is selected using bit 7, the time-out length for a single page for all
modes will depend on the setting of bit 0 and bit 1.
T-8-7
T-8-8
Time-Out Length for Transmission/reception
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
8min.
0
*
*
*
*
*
0
0
16min.
0
*
*
*
*
*
0
1
32min.
0
*
*
*
*
*
1
0
64min.
0
*
*
*
*
*
1
1
Time-Out Length for Transmission (text mode)
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
8min.
1
*
*
*
*
*
0
0
16min.
1
*
*
*
*
*
0
1
32min.
1
*
*
*
*
*
1
0
64min.
1
*
*
*
*
*
1
1
Time-Out Length for Transmission (image mode other than text mode)
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
8min.
1
*
*
*
0
0
*
*
16min.
1
*
*
*
0
1
*
*
32min.
1
*
*
*
1
0
*
*
64min.
1
*
*
*
1
1
*
*
Time-Out Length for Reception
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
8min.
1
*
0
0
*
*
*
*
16min.
1
*
0
1
*
*
*
*
32min.
1
*
1
0
*
*
*
*
64min.
1
*
1
1
*
*
*
*
●
SSSW-SW013
List of Functions
Bit
Function
1
0
0
not used
-
-
1
not used
-
-
2
Convert "inch" into "mm" when transmitting the
received image data
convert
do not convert
T-8-9
T-8-10
T-8-11
T-8-12
Summary of Contents for imageRUNNER 2545
Page 15: ...1 1 Product Overview Product Overview Product Lineup Feature Specifications Name of Parts...
Page 105: ...3 3 Periodical Service Periodical Service Consumable Parts and Cleaning Parts...
Page 177: ...5 5 Adjustment Adjustment Outline Adjustment when replacing parts Image position adjustment...
Page 195: ...7 7 Error Code Overview Error Code Jam Code Alarm Code...
Page 205: ...7 7 7 11 7 11...
Page 211: ...8 8 Service Mode Outline Details of Service Mode...
Page 354: ...Service Tools General Circuit Diagram Appendix...