7) Remove the connection cable.
2 connectors (The machine without the No.2 delivery unit does not have the upper
connector.)
CAUTION:
Be sure to disconnect the upper connector after releasing the harness from the clamp
to prevent breaking of wire
8) Remove one screw.
x1
x2
9)Remove two screws.
x2
F-4-47
F-4-48
10)Remove the right cover assembly.
F-4-49