White spots appear at 68mm intervals
Description
Because of a soiling on the secondary transfer internal roller, white spots appeared at 68mm
intervals. When the same symptom occurs, perform the following field remedy.
Cause
A metal powder soiling existed on the surface of the secondary transfer internal roller.
Field Remedy
1. Taking care not to cause damage to the ITB belt, detach the secondary transfer internal
roller unit [A], and then clean the secondary transfer internal roller [B] with lint-free paper
moistened with alcohol.
3. Return the detached secondary transfer internal roller unit, and then make copies to
check output images.
FC5-9252 Transfer Roller2
Summary of Contents for imagePRESS C7000VP Series
Page 17: ...Trouble Shooting Information for C7000VP series Page 17 Rev 2 0 2010 09 17 ...
Page 32: ...Trouble Shooting Information for C7000VP series Page 32 Rev 2 0 2010 09 17 ...
Page 33: ...Trouble Shooting Information for C7000VP series Page 33 Rev 2 0 2010 09 17 ...
Page 34: ...Trouble Shooting Information for C7000VP series Page 34 Rev 2 0 2010 09 17 ...
Page 35: ...Trouble Shooting Information for C7000VP series Page 35 Rev 2 0 2010 09 17 ...
Page 36: ...Trouble Shooting Information for C7000VP series Page 36 Rev 2 0 2010 09 17 ...
Page 37: ...Trouble Shooting Information for C7000VP series Page 37 Rev 2 0 2010 09 17 ...
Page 38: ...Trouble Shooting Information for C7000VP series Page 38 Rev 2 0 2010 09 17 ...
Page 39: ...Trouble Shooting Information for C7000VP series Page 39 Rev 2 0 2010 09 17 ...
Page 40: ...Trouble Shooting Information for C7000VP series Page 40 Rev 2 0 2010 09 17 ...
Page 41: ...Trouble Shooting Information for C7000VP series Page 41 Rev 2 0 2010 09 17 ...
Page 133: ...Trouble Shooting Information for C7000VP series Page 133 Rev 2 0 2010 09 17 ...
Page 134: ...Trouble Shooting Information for C7000VP series Page 134 Rev 2 0 2010 09 17 ...