Closing the imagePASS
As part of servicing the imagePASS, you may need to open the imagePASS (see
).
Before you open the imagePASS, you must disconnect cables, and then remove the
imagePASS from the copier (
After you service the imagePASS, make sure you close the imagePASS correctly.
T
O
CLOSE
THE
IMAGE
PASS
When you handle electronic components, follow electrostatic discharge (ESD) precautions
(see
1 Place the lid on the chassis.
2 Secure the lid to the chassis with the two screws that you removed earlier.
Service modes
Service switches and an LED are located on the outside of imagePASS, on the side opposite
the connector panel.
With the service switches, you can change the mode of the imagePASS, a required step in
some service procedures. With the LED, you can monitor the progress of an installation and
view service codes, which provide information about the status of the imagePASS.
During startup, the imagePASS advances through a standard diagnostic sequence. Codes flash
rapidly on the LED display during this time, until the imagePASS reaches Idle. In the Idle
state,
00
displays. If the LED display hangs with a code other than
00
, one or more diagnostic
tests may have failed. For more information about service codes, see
F
IGURE
4:
Service modes
1 Normal mode
2 Service mode for installing
system software through a
USB flash drive (see
3 Service mode for installing
system software though an
Ethernet port (see