29
SYSTEM 2316E/2316EC Installation Manual
Program Option
CL
Program Function
Comments
Audible/Visual Switches 2E (1 & 2)
Entry/Exit
If Digit Position (1) is programmed for Entry Pre-Alarm, the
Pre-Alarm
keypad will sound continuously for all but the last 10 seconds
of the amount of time programmed for the Entry Delay Time
(CL 2D (3)). The keypad will beep for the last 10 seconds of the
Entry Delay. If Digit Position (2) is programmed for Exit Pre-
Alarm, the keypad will beep for the time programmed into CL
2D (4), Exit Delay Time. The speed at which the keypad beeps
will increase during the last 10 seconds of the Delay time.
Alpha Plus keypads will display a bar graph in addition to the
audible tone.
Unit Control
2F (3)
Enable 4-minute
Suppresses all trouble and alarm reports for a period of four
Power-Up
minutes after power is initially applied to the panel. This allows
Delay
the sensors, such as PIRs time to stabilize when initializing or
prevents powered devices, such as smoke detectors, from
sending alarms when first starting panel with a dead battery or
no battery connected.
Loop Switches
30 - 3F (3) Allow Group
This allows multiple loops to be shunted simultaneously with
Shunting
a single keypad command. This is typically done on all interior
loops in a system. The command also Arms or Instant Arms
the system. (See page 24 for Group Bypassing and Instant
Arm.)
Loop Switches
30 - 3F (4) Delay Before Dial
This option programs the loops to have a delay after they are
triggered to allow the User time to shut down the system in the
event of an accidental triggering of the zone. The amount of
time is determined by the value programmed into CL 0B Digit
Position (1). The time delay may be between 10 and 150
seconds, in 10 second intervals.