SYSTEM 2316E/2316EC  Installation Manual

FCC Notice

This equipment complies with FCC Rules, Part 68.
On the outside of this equipment is a label that contains, among other infor-

mation, the FCC Registration Number and Ringer Equivalence Number (REN)

for this equipment. If requested, provide this information to your telephone

company.
The REN is useful to determine the quantity of devices you may connect to

your telephone line and still have all of those devices ring when your number

is called. In most, but not all areas, the sum of the REN’s devices should not

exceed five (5.0). To be certain of the number of devices you may connect to

your line, as determined by the REN, you should call your local telephone

company to determine the maximum REN for your calling area.
Should you experience trouble with the telephone lines, disconnect the equip-

ment from the line to determine the source of the trouble. If it is determined

that the equipment is malfunctioning, discontinue its use until the malfunc-

tion has been corrected. Any repairs or alterations made by the user to this

equipment,  or  equipment  malfunctions,  may  give  the  telephone  company

Industry Canada

NOTICE: The Industry Canada label identifies certified equipment. This certi-

fication means that the equipment meets telecommunications network pro-

tective, operational and safety requirements as prescribed in the appropriate

Terminal  Equipment  Technical  Requirements  documents.  The  Department

does not guarantee the equipment will operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to

be connected to the facilities of the local telecommunications company. The

equipment must also be installed using an acceptable method of connection.

The customer should be aware that compliance with the above conditions

may not prevent degradation of service in some situations.
Repairs to certified equipment should be coordinated by a representative des-

ignated by the supplier. Any repairs or alterations made by the user to this

equipment,  or  equipment  malfunctions,  may  give  the  telecommunications

company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground con-

nections of the power utility, telephone lines and internal metallic water pipe

system, if present, are connected together. This precaution may be particu-

larly important in rural areas.

Caution:

 Users should not attempt to make such connections themselves,

but  should  contact  the  appropriate  electric  inspection  authority,  or  electri-

cian, as appropriate.

NOTICE: The Ringer Equivalence Number 

(REN) assigned to each termi-

nal  device  provides  an  indication  of  the  maximum  number  of  terminals  al-

lowed to be connected to a telephone interface. The termination on an inter-

face may consist of any combination of devices subject only to the require-

ment that the sum of the Ringer Equivalence Numbers of all the devices does

not exceed 5.

This Class B digital apparatus meets all requirements of the Canadian Inter-

ference-Causing Equipment Regulations.
Cet  appareil  numérique  de  la  classe  B  respecte  toutes  les  exigences  du

Règlement sur le matériel brouilleur du Canada.

IC Certification: 1140  9153  A

Ringer Equivalence: 0.5

Table of Contents

Subject

Page No.

FCC Notice

2

Industry Canada

2

Introduction

3

UL Compliance

3

Zone Programming

3

European Compliance

3

Installation

3

Mounting

3

System 2316E Terminal Label

4

System 2316EC Terminal Label

5

Before You Start

6

Wiring the Panel

6

Standby Battery

6

AC Power (System 2316E)

6

AC Power (System 2316EC)

6

Audible Output

6

Setting Up the 2350-SUP

6

Auxiliary Power (Switched and Unswitched)

7

Arming Stations

7

Loop Inputs

8

Tamper Switch Installation

8

Telephone Interface

9

System Start-Up

9

Standby Battery Time

9

Voltage Variations

9

Factory Settings

9

Default Program Setup

9

Programming Options (Alphabetical List)

10

Programming the Panel

10

Starting Panel Programming

10

Programming with the LED Plus Keypad

10

Programming with the Alpha Plus Keypad

11

Programming Hexadecimal Numbers

11

End of Programming Segment

11

Programming the Alpha Plus Keypad

11

Keypad Message Programming

11

Programming Options (Numerical Order)

12

End-User Information

24

Testing

24

To the Installer

24

Telephone Line Problems

24

Watchdog Indicator

24

Limitations of Your Alarm System

24

Keypad Operation Command Summary

25

Survey of Most Common Questions

26

Recommendations for Reducing False Alarms

28

Programming Worksheets

30

cause to request the user to disconnect the equipment. Repairs to this equip-

ment should be made by an authorized agent of C&K Systems, Inc. Contact

your local alarm installation company for service.
Should this equipment cause harm to the telephone network, the telephone

company may temporarily discontinue your service. If possible, they will pro-

vide you with advance notice. Otherwise they will notify you as soon as pos-

sible. The telephone company will also advise you of changes in its facilities,

equipment, operations or procedures which could affect the operation of your

equipment, allowing you the opportunity to maintain uninterrupted service.

You will also be advised of your right to file a complaint with the FCC.
This equipment must not be used on party lines or coin operated phone lines.

FCC Part 15 Notice

This equipment has been tested and found to comply with the limits for Class

B digital devices, pursuant to Part 15 of the FCC Rules. These limits are de-

signed to provide reasonable protection against harmful interference in a resi-

dential installation.
This  equipment  generates,  uses,  and  can  radiate  radio  frequency  energy,

and if not installed and used in accordance with the instructions, may cause

harmful interference to radio communications. However, there is no guaran-

tee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television re-

ception, which can be determined by turning the equipment off and on, the

user is encouraged to try to correct the interference by one or more of the

following measures:

–

Reorient the radio/television antenna;

–

Connect the AC transformer to a different outlet so that the equipment and

radio/television are on different branch circuits;

–

Relocate the equipment with respect to the radio/television;

–

Consult the dealer or an experienced radio/television technician for help.

FCC Registration Number: C2DCHN-25602-AL-E

Ringer Equivalence: 0.67B

Summary of Contents for System 2316E

Page 1: ...SYSTEM 2316E and SYSTEM 2316EC 16 Zone Control Panel Installation Instructions P N 5 051 507 00 Rev A ...

Page 2: ...e toutes les exigences du Règlement sur le matériel brouilleur du Canada IC Certification 1140 9153 A Ringer Equivalence 0 5 Table of Contents Subject Page No FCC Notice 2 Industry Canada 2 Introduction 3 UL Compliance 3 Zone Programming 3 European Compliance 3 Installation 3 Mounting 3 System 2316E Terminal Label 4 System 2316EC Terminal Label 5 Before You Start 6 Wiring the Panel 6 Standby Batte...

Page 3: ...igid conduit or electric metallic tubing for a Grade A system or flexible conduit for a Grade B system 7 Zone s monitoring tamper circuitry must be 24 hours and non shuntable INSTALLATION Mounting The System 2316E 2316EC should be mounted in a location that allows convenient access to AC power telephone connections and earth ground 1 Remove the circuit board from the cabinet This will prevent pos ...

Page 4: ...4 SYSTEM 2316E 2316EC Installation Manual SYSTEM 2316E Terminal Label Figure 2 System 2316E Terminal Layout ...

Page 5: ...5 SYSTEM 2316E 2316EC Installation Manual SYSTEM 2316EC Terminal Label Figure 3 System 2316EC Terminal Layout ...

Page 6: ...re report will be sent if pro grammed When AC is restored for five minutes a restoral report will be sent ECKHA Available Power The maximum total power available from the Siren SWAUX AUX and KPD Terminals is 750 mA The switched auxiliary SWAUX unswitched auxiliary AUX and keypads KPD share the same power bus Current draw must be reduced to 120 mA System 2316E only to achieve a battery backup time ...

Page 7: ...outputs on the System 2316E are electronically protected against overload conditions by a self resetting circuit There are no user replaceable parts used The SWAUX and AUX outputs on the System 2316EC are protected by a 0 75 A 3AG fast blow fuse F2 Arming Stations C KPD KDATA Terminals The KPD Terminal red provides 11 14 VDC to power the keypads The KPD terminal of the control panel connects to th...

Page 8: ...N OFF OFF ON ON OFF OFF S1 1 ON OFF ON OFF ON OFF ON OFF ADDRESS 8 9 10 11 12 13 14 15 S1 3 ON ON ON ON OFF OFF OFF OFF Switch S1 4 must ON for the System 2316E or 2316EC NOTE Once all keypads have been addressed reset the panel by pressing Master Combination 6 8 or by removing and restoring both AC and DC power N O Alarm N C Alarm When operated as a Super vised Loop an open will be reported as a ...

Page 9: ...nnect the control panel to the incoming phone lines and the house phones Using an approved 6 or 8 conductor telephone cable not included con nect the cable to the control panel as listed below Red Incoming Ring Brown Seized Tip T1 Green Incoming Tip Blue Orange Tamper Gray Seized Ring R1 Yellow Black Not Used Figure 10 Telco Connections Combinations Installer combination 0 1 2 3 4 5 User 1 Master ...

Page 10: ...r 0D 0F 1 6 Receiver 1 Receiver Format 0A 1 Receiver 2 Message Format 0A 4 Receiver 2 Phone Number 11 13 1 6 Receiver 2 Receiver Format 0A 3 Restore Receiver Select 2A 2 Restore Reporting Code by Loop 17 1E 40 47 3 4 Ring Back Enable 2E 4 RPS Enable 0B 4 RPS Phone Number 14 16 1 6 Set Test Report Countdown Timer A0 1 Set Real Time Clock B3 B4 1 6 Shunt Enable 30 3F 2 Shunt Receiver Select 2A 1 Shu...

Page 11: ...ssage position Use the 0 key to move backward through the messages The message order is as follows SERVICE MESSAGE DEALER MESSAGE SOFT ZONE IDENTIFIERS A B and C HARDWIRED LOOP IDENTIFIERS KEYPAD ADDRESS You can program the Alpha Plus keypads for special messages each of the 16 zone labels and the keypad address Zone Labels display during the walk test and when the key is pressed during alarm memo...

Page 12: ...Only with Opening Report Shunting Allowed 2 Arm and Disarm with O C Reports Shunting Allowed 7 Arm Only No Closing Report Shunting Allowed 8 Disarm Only No Opening Report Shunting Allowed 9 Arm and Disarm No O C Reports Shunting Allowed 4 Arm Only with Closing Report No Shunting 5 Disarm Only with Opening Report No Shunting 6 Arm and Disarm with O C Reports No Shunting Digit Positions 2 6 Arming C...

Page 13: ...9 and 0A Default Values 2 3 4 5 0 1 1 0 0 0 9 Digit Position 5 Autohome Enable 0 No this disables the Autohome Arming feature 1 Yes when enabled automatically shunts all zones designated as Group Shunt if exit door is not opened during Exit Delay See CL 30 3F Digit Position 3 for Group Shunt Enable option Command Location 0A Communications Formats 1 2 3 4 1 2 1 2 Default Values 0 A Digit Position ...

Page 14: ... 3 3 tries 4 4 tries 5 5 tries 6 6 tries 7 7 tries 8 8 tries 9 9 tries 0 10 tries 1 11 tries 2 12 tries 3 13 tries 4 14 tries 5 15 tries 1 2 3 4 5 6 0 0 0 0 0 0 C 0 Default Values Digit Positions 1 6 Account Number Validentriesare0 F TheAccountNumberisrightjustified ThelastdigitmustbeinPosition 6 TheSYSTEM2316E 2316ECwillreadtheaccountnumberusing DigitPositions 4 6 with3 digitaccounts DigitPositio...

Page 15: ...n 10 Account Number 2 1 0 1 2 3 4 5 6 0 0 0 0 0 0 Account Number 2 is used in conjunction with Receiver Number 2 Digit Positions 1 6 Account Number Valid entries are 0 F The Account Number is right justified The last digit must be in Position 6 The SYSTEM 2316E 2316EC will read the account number using Digit Positions 4 6 with 3 digit accounts Digit Positions 3 6 with 4 digit accounts Digit Positi...

Page 16: ...3 4 6 0 0 0 0 0 0 Default Values Command Location 12 Receiver 2 Phone Number digits 7 12 Command Location 13 Receiver 2 Phone Number digits 13 18 1 3 1 2 3 4 5 6 0 0 0 0 0 0 Default Values Command Locations 14 16 RPS Phone Number Command Location 14 RPS Phone Number digits 1 6 1 4 1 2 3 4 5 6 E 0 0 0 0 0 Default Values Command Location 15 RPS Phone Number digits 7 12 1 5 1 2 3 4 5 6 0 0 0 0 0 0 De...

Page 17: ...f this manual Digit Position 2 Loop Response Time Digit Position 1 Alarm Receiver Select 0 Receiver 1 with Receiver 2 as backup 1 Receiver 1 only 2 Receiver 2 only 3 Receiver 1 and Receiver 2 Dual Reporting 0 5 milliseconds 1 250 milliseconds 2 500 milliseconds 3 750 milliseconds Digit Position 3 Loop Restore Type 0 No Restoral Report sent 1 Restoral sent when loop normal 2 Restoral sent when loop...

Page 18: ...t Position 3 Fire Receiver Select Digit Position 4 Fire Loop Bell Type A B C D E F Hexadecimal Value Key Strokes 0 1 2 3 4 5 PROGRAMMING CONVERSIONS CL 27 29 Command Location 29 Soft Zone C Police 1 2 3 4 0 0 1 3 Default Values 2 9 Digit Positions 1 and 2 Police Report Code Digit Position 3 Police Zone Receiver Select Digit Position 4 Police Loop Bell Type Refer to CL 27 for information about prog...

Page 19: ...Digit Position 6 Cancel Report Receiver Select 0 Receiver 1 with Receiver 2 as backup 1 Receiver 1 only 7 AC restore 8 Bell fuse restore B Watchdog reset C Completed programming 1 Low battery 2 AC fail 3 Bell fuse fail 5 Failed to communicate 6 Battery restore UNIT STATUS FIXED EXTENSION CODES Command Location 2B Test Report 1 2 3 4 0 0 1 6 Default Values 2 B 0 Receiver 1 with Receiver 2 as backup...

Page 20: ...ault Values 1 2 3 4 5 1 3 6 2 0 2 D Digit Position 1 Duress Report Code Valid entries are 0 F The User ID will be reported as the second digit when reporting Program 0 to disable Duress Reports Digit Position 2 Duress Receiver Select 0 Receiver 1 with Receiver 2 as backup 1 Receiver 1 only 2 Receiver2only 3 Receiver 1 and Receiver 2 Dual Reporting Digit Position 3 Entry Delay Time NOTE To program ...

Page 21: ...upervised accounts sounds bells for 2 seconds Digit Position 5 Disable Loop LEDs 0 No 1 Yes turns off keypad zone LEDs after 5 minutes Command Location 2F Unit Control Default Values 1 2 3 4 5 0 0 1 1 1 2 F Digit Position 1 Local System Only 0 No 1 Yes disables all communications except RPS Digit Position 2 Daily Dynamic Battery Test Enable 0 No 1 Yes performs a 2 minute battery test under load co...

Page 22: ...e Arming or Instant Home Arming feature See CL 09 Digit Position 5 and pages 25 29 Digit Position 4 Delay Before Dial 0 No 1 Yes this loop will delay dialing on alarm for time programmed in 0B 1 Command Location 48 Trouble Reports 1 2 3 4 F 1 E 1 Default Values 4 8 Digit Position 1 Trouble Report Code Thisisaone digitreportingcode Program 0 to disable Trouble Report Digit Position 2 Trouble Report...

Page 23: ...it Position 5 Day 10s Digit Position 6 Day 1s 1 2 3 4 5 6 B 3 9 8 0 2 1 2 Example IfthedatewereFebruary12 1998 B3wouldbeprogrammed YEAR MONTH DAY Command Location A0 Test Report Countdown Timer This command will set the time when the first Test Report is transmitted to the central station The panel will use this transmission time each time it s powered up or the CPU is reset unless Command Locatio...

Page 24: ...gn security system it does not offer guaranteed protection against burglary fire or other losses Any alarm system whether commercial or residential is subject to compromise or failure to warn for a variety of reasons These include Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device Intrusion det...

Page 25: ...mally upon expiration of Exit Delay all delayed zones are converted to Instant No Entry Delay Combo may be required Also called Instant Home Arming Instant Arm Arms system and converts delayed zones to Combination 7 Instant Exit Delay active No Entry Delay Combo may be required Keypad Activated RPS If enabled CL 0B 3 Combo may be required Combination 0 2 Medical Alarm Keypad activated E Hold for 3...

Page 26: ... line Green wire between the panel and the keypad Check the connection to ensure that the wire is not pinched or loose Also try disconnecting all key pads from the panel one at a time resetting the panel after each keypad is removed Remember to reset the panel press Master Combination 6 8 Question How do I reset Alarm Memory Answer To Clear Alarm Memory press 1 Question How do I address an Alpha P...

Page 27: ...forget to reset the panel Master Combination 6 8 after changing the address so the panel knows how to properly address the keypad For additional information about keypad addressing see page 7 Question Why can t my panel communicate with the Central Station Answer There are several reasons for the panel not communicating The first place to look is CL 2F 1 This is the Unit Control if Digit Position ...

Page 28: ...buffer on the loop to minimize the possibility of fast acting sensors such as swingers or window foil produc ing false alarms Loop Control 1F 26 Loop Restore Type This option is used in conjunction with CL 17 1E 40 47 49 50 3 Digit Positions 3 4 Restore Reporting Code and CL 2A 2 Restore Receiver Select The panel can be programmed to send a Restoral Report only when the loop is normal and the syst...

Page 29: ...orts for a period of four Power Up minutes after power is initially applied to the panel This allows Delay the sensors such as PIRs time to stabilize when initializing or prevents powered devices such as smoke detectors from sending alarms when first starting panel with a dead battery or no battery connected Loop Switches 30 3F 3 Allow Group This allows multiple loops to be shunted simultaneously ...

Page 30: ...SYSTEM 2316E 2316EC Installation Manual 30 C K is a registered trademark of C K Components Inc Copyright 1998 C K SYSTEMS Inc All Rights Reserved 5 051 507 00 Rev A ...

Page 31: ... 4 5 6 7 0 0 0 1 2 3 4 5 Installer Combination 5 8 9 E 0 0 0 0 User 16 Name 5 7 9 E 0 0 0 0 User 15 Name 5 6 9 E 0 0 0 0 User 14 Name 5 5 9 E 0 0 0 0 User 13 Name 5 4 9 E 0 0 0 0 User 12 Name 5 3 9 E 0 0 0 0 User 11 Name 5 2 9 E 0 0 0 0 User 10 Name 5 1 9 E 0 0 0 0 User 9 Name 0 8 9 E 0 0 0 0 User 8 Guest Name 0 7 9 E 0 0 0 0 User 7 Name 0 5 9 E 0 0 0 0 User 5 Name 0 6 9 E 0 0 0 0 User 6 Name 0 4 ...

Page 32: ...hone 1 1st 6 digits 0 D 0 0 0 0 0 E Last 6 digits 0 F 0 0 0 0 0 0 Middle 6 digits 0 E 0 0 0 0 0 0 1 0 0 0 0 0 0 0 Account 2 Phone 2 1st 6 digits 1 1 0 0 0 0 0 E Last 6 digits 1 3 0 0 0 0 0 0 Middle 6 digits 1 2 0 0 0 0 0 0 RPS Phone 1st 6 digits 1 4 0 0 0 0 0 E Last 6 digits 1 6 0 0 0 0 0 0 Middle 6 digits 1 5 0 0 0 0 0 0 8 9 E 0 0 0 0 9 E 0 0 0 0 9 E 0 0 0 0 9 E 0 0 0 0 9 E 0 0 0 0 9 E 0 0 0 0 9 ...

Page 33: ...1 1 3 3 Loop 9 Control 4 A 1 2 1 1 3 3 Loop 10 Control 4 B 1 2 1 1 3 3 Loop 11 Control 1 9 0 3 E 3 0 0 Loop 3 Codes 1 8 0 2 E 2 0 0 Loop 2 Codes 1 A 0 4 E 4 0 0 Loop 4 Codes 1 B 0 5 E 5 0 0 Loop 5 Codes 1 C 0 6 E 6 0 0 Loop 6 Codes 1 D 0 7 E 7 0 0 Loop 7 Codes 4 0 0 9 E 9 0 0 Loop 9 Codes 1 E 0 8 E 8 0 0 Loop 8 Codes 4 1 1 0 E A 0 0 Loop 10 Codes 4 2 1 1 E B 0 0 Loop 11 Codes 4 3 1 2 E C 0 0 Loop ...

Page 34: ...Visual Switches 0 0 1 6 2 B Test Report 0 1 3 6 2 2 D Duress Delays 1 0 0 1 1 2 F Unit Control 1 0 0 3 0 Loop 1 Switches 0 1 0 0 3 2 Loop 3 Switches 0 1 0 0 3 4 Loop 5 Switches 0 1 0 0 3 6 Loop 7 Switches 0 1 0 0 3 8 Loop 9 Switches 0 1 0 0 3 A Loop 11 Switches 0 1 0 0 3 C Loop 13 Switches 0 0 1 0 0 3 E Loop 15 Switches 0 1 0 0 3 1 Loop 2 Switches 0 1 0 0 3 3 Loop 4 Switches 0 1 0 0 3 5 Loop 6 Swi...