![background image](http://html.mh-extra.com/html/candk-systems/system-2316e/system-2316e_installation-instructions-manual_478078010.webp)
10
SYSTEM 2316E/2316EC Installation Manual
Testing
Test report interval: 7 days and disabled
Timing
Entry time: 60 seconds and prewarn
Exit time: 30 seconds and prewarn
Bell time: 5 minutes
Unit Control
Local system: yes
Dynamic battery test: off
PROGRAMMING OPTIONS
The following is an alphabetical listing of all System 2316E/2316EC
programming options, including Command Locations and Digit Posi-
tions. Digit Positions are inside parentheses ( ).
NOTE:
All Command
Locations are in Hexadecimal.
Option
Location
Account #1
0C (1 - 6)
Account #2
10 (1 - 6)
AC Power Line Frequency
2F (5)
Alarm Receiver Select by Loop
1F - 26 & 49 - 50 (1)
Alarm Reporting Code by Loop
17 - 1E & 40 - 47 (1 - 2)
Audible Time
2D (5)
Autohome Enable
09 (5)
Bell Reverse Operation
2E (3)
Cancel Report Code
2A (5)
Cancel Report Receiver Select
2A (6)
Closing Report Code
2C (3)
Closing Report Receiver Select
2C (4)
Combination Command
09 (2)
Daily Battery Test Enable
2F (2)
Default Installer Combination
09 (3)
Delay Before Dial by Loop
30 - 3F (4)
Delay Before Dial Time
0B (1)
Dial Attempts
0B (6)
Dial Type
0B (2)
Disable Loop LEDs
2E (5)
Door Chime Enable by Loop
30 - 3F (1)
Duress Report Code
2D (1)
Duress Receiver Select
2D (2)
Emergency Bell Type
27 (4)
Emergency Receiver Select
27 (3)
Emergency Report Code
27 (1 - 2)
Entry Delay Time
2D (3)
Entry Pre-alarm Enable
2E (1)
Exit Delay Time
2D (4)
Exit Pre-alarm Enable
2E (2)
Faulted Arming Type
09 (4)
Fire Bell Type
28 (4)
Fire Receiver Select
28 (3)
Fire Report Code
28 (1 - 2)
Four Minute Power Up Delay Enable
2F (3)
Group Shunt Enable
30 - 3F (3)
Guest Combination
08 (2 - 6)
Guest Combination Time
09 (1)
Installer Combination
00 (1 - 6)
Keypad RPS Enable
0B (3)
Local System Only
2F (1)
Loop Arming Type
1F - 26 & 49 - 50 (4)
Loop Bell Type
1F - 26 & 49 - 50 (5)
Loop Circuit Type
1F - 26 & 49 - 50 (6)
Loop Response Time
1F - 26 & 49 - 50 (2)
Loop Restore Type
1F - 26 & 49 - 50 (3)
Master Code (User #1)
01 (2 - 6)
Opening Report Code
2C (1)
Opening Report Receiver Select
2C (2)
Phone Ring Type
0B (5)
Police Bell Type
29 (4)
Police Receiver Select
29 (3)
Police Report Code
29 (1 - 2)
Receiver #1 Message Format
0A (2)
Receiver #1 Phone Number
0D - 0F (1 - 6)
Receiver #1 Receiver Format
0A (1)
Receiver #2 Message Format
0A (4)
Receiver #2 Phone Number
11 - 13 (1 - 6)
Receiver #2 Receiver Format
0A (3)
Restore Receiver Select
2A (2)
Restore Reporting Code by Loop
17 - 1E & 40 - 47 (3 - 4)
Ring Back Enable
2E (4)
RPS Enable
0B (4)
RPS Phone Number
14 - 16 (1 - 6)
Set Test Report Countdown Timer
A0 (1)
Set Real-Time Clock
B3 & B4 (1 - 6)
Shunt Enable
30 - 3F (2)
Shunt Receiver Select
2A (1)
Shunt Reporting Code by Loop
17 - 1E & 40 - 47 (5 - 6)
Soft Zone Operation Enable
2F (4)
Test Report Code
2B (1 - 2)
Test Report Interval
2B (4)
Test Report Receiver Select
2B (3)
Trouble Report Code
48 (1)
Trouble Report Receiver Select
48 (2)
Trouble Restore Code
48 (3)
Trouble Restore Receiver Select
48 (4)
Unit Status Code
2A (3)
Unit Status Receiver Select
2A (4)
User Arming Type
01 - 08 & 51 - 68 (1)
User Combinations
01 - 08 & 51 - 68 (2 - 6)
Option
Location
PROGRAMMING THE PANEL
You can program the SYSTEM 2316E/2316EC from an LED or LCD
keypad, as well as remotely using the COMMANDER II software. Infor-
mation on remote programming is available in the COMMANDER II/
MONITOR II Operating Manual. This installation manual includes a brief
description of each programming option beginning on page 12.
Starting Panel Programming
To activate installer programming, key in the [Installer Combination] [*] [0]
[#]. The default Installer Combination is
0 1 2 3 4 5
. When using an LED Plus
keypad, the PROGRAM LED will light to indicate that you are in the
programming mode. The LCD display of the Alpha Plus keypad will read
CMD DATA
on the top line, indicating that the programming mode is active.
Zones
Zone 1 = Entry/Exit delay - EOL circuit
Zone 2 = doors or windows - EOL circuit
Zone 3 = doors or windows - EOL circuit
Zone 4 = doors or windows - EOL circuit
Zone 5 = doors or windows - EOL circuit
Zone 6 = doors or windows - EOL circuit
Zone 7 = doors or windows - EOL circuit
Zone 8 = fire or smoke - supervised EOL circuit
Zone 9 = interior - EOL circuit
Zone 10 = interior - EOL circuit
Zone 11 = interior - EOL circuit
Zone 12 = interior - EOL circuit
Zone 13 = interior - EOL circuit
Zone 14 = interior - EOL circuit
Zone 15 = interior - EOL circuit
Zone 16 = interior - EOL circuit
Emergency soft zone: steady audible, non-reporting
Fire soft zone: 3-pulse temporal audible, non-reporting
Police soft zone: pulsing audible, non-reporting