The following keypad commands apply to both the LED and Alpha Plus keypads:
KEYPAD OPERATION COMMAND SUMMARY
Function
Comments
Keystroke Sequence
Arm/Disarm
Delays active
[Combination] [#]
Arm Tones Toggle On/Off
[*] [5] [4] [#]
Audible Feedback Toggle
[*] [5] [1] [#]
Bypass Zone (n)
[n] is zone # 1 - 16; Combo may be
[Combination] [Bypass] [n] [#]
required
Chime On/Off
Turns system Chime on/off (Combo may be
[Combination] [*] [5] [#]
required)
Chime Toggle
Toggles Chime feature on keypad only
[*] [5] [3] [#]
Change Combo using
Must be done from User #1
[Master Combo] [*] [0] [#] [User Number]
Master Combo
[New Combo] [#] [New Combo] [#]
Clear Alarm Memory
[*] [1] [#]
Exit Programming
[*] [#]
Fire Alarm
Keypad activated
[F] (Hold for 3 seconds)
Group Shunt and Arm
Arms the system and all zones programmed for
[Combination] [*] [4] [#]
group bypass, CL 30 - 3F, Digit Position (3),
are shunted simultaneously; Combo may be
required
(This is also called Home-Arming)
Group Shunt and Instant
Same as Group Bypass (above) except system [Combination] [*] [4] [7] [#] or
Arm
is Instant Armed (Exit Delay operates
[Combination] [*] [7] [4] [#]
normally, upon expiration of Exit Delay, all
delayed zones are converted to Instant - No
Entry Delay). Combo may be required
(Also called Instant Home-Arming)
Instant Arm
Arms system and converts delayed zones to
[Combination] [*] [7] [#]
Instant (Exit Delay active, No Entry Delay),
Combo may be required
Keypad Activated RPS
If enabled, CL 0B(3); Combo may be required [Combination] [*] [0] [2] [#]
Medical Alarm
Keypad activated
[E] (Hold for 3 seconds)
Police/Panic Alarm
Keypad activated
[P] (Hold for 3 seconds)
Pre-warn Toggle On/Off
[*] [5] [2] [#]
Reset Aux Power
If resettable devices are connected to
[*] [6] [2] [#]
Terminals 5 and 6
Reset Panel
[Master Combination] [*] [6] [8] [#]
Test - Battery
Use after correcting Low Battery problem
[*] [6] [4] [#]
Test - Bells
Combo may be required
[Combination] [*] [6] [3] [#]
Test - Central Station
Combo may be required
[Combination] [*] [6] [1] [#]
Test - Local Walk-Test
[*] [6] [0] [#]
NOTE:
For additional information about Combination Command requirements, see page 27 and CL 09 (2).
The following Keypad Commands apply to the Alpha Plus keypad only:
Function
Comments
Keystroke Sequence
Backlight Toggle On/Off
[*] [8] [#]
Display Keypad Model
[*] [9] [#]
& Revision Number
The following keypad commands are Installer Only Commands:
Function
Comments
Keystroke Sequence
Alpha Keypad Programming Start Programming the Keypad
[Installer Combination] [*] [0] [1] [#]
Alpha Keypad Test
[*] [6] [7] [#]
Kill/Revive Panel
[Installer Combination] [*] [6] [9] [#]
Panel Programming
Start Programming the Panel
[Installer Combination] [*] [0] [#]