![Camozzi PME Series Operation & Maintenance Instructions Manual Download Page 38](http://html1.mh-extra.com/html/camozzi/pme-series/pme-series_operation-and-maintenance-instructions-manual_3055598038.webp)
Operation and maintenance instructions
Series PME CANopen proportional pressure
regulator
5000054187
Ver. 01
38
ID
SUB
DESCRIPTION
TYPE ACCESS
PDO
MAPPING
DEFAUL VALUE
4
Compatibility entry
U8
RW
0x0
5
Event timer
U16
RW
0x0
1805h
Tx PDO communication
parameter 6
0
Sub-index supported
U8
RO
0x5
1
COIB-ID
U32
RW
0x80000000
2
Transmission type
U8
RW
0xFF
3
Inhibit time
U16
RW
0x0
4
Compatibility entry
U8
RW
0x0
5
Event timer
U16
RW
0x0
1806h
Tx PDO communication
parameter 7
0
Sub-index supported
U8
RO
0x5
1
COIB-ID
U32
RW
0x80000000
2
Transmission type
U8
RW
0xFF
3
Inhibit time
U16
RW
0x0
4
Compatibility entry
U8
RW
0x0
5
Event timer
U16
RW
0x0
1807h
Tx PDO communication
parameter 8
0
Sub-index supported
U8
RO
0x5
1
COIB-ID
U32
RW
0x80000000
2
Transmission type
U8
RW
0xFF
3
Inhibit time
U16
RW
0x0
4
Compatibility entry
U8
RW
0x0
5
Event timer
U16
RW
0x0
1A00h
Tx PDO mapping parameter 1
0
Number of mapped objects
U8
RW
0x2
1
Mapping entry 1
U32
RW
0x60410010
2
Mapping entry 2
U32
RW
0x63810110
3..8
Mapping entry X
U32
RW
0X0
1A01h
Tx PDO mapping parameter 2
0
Number of mapped objects
U8
RW
0x0