Electrical power supply
12 -10% 24 +10% Vdc
Current consumption
Max 0,250A (refer to the table below for more details)
Hysteresis (*)
0,5% FS
0,7% FS
Repeatability (*)
0,4% FS
0,4% FS
Linearity (*)
0,3% FS
0,3% FS
Resolution (*)
0,3% FS
0,6% FS
Overpressure discharge
With relieving
Modularity
With Series MD
(*) measured with Inlet pressure = Maximum regulated pr 1bar and a volume
connected to the outlet without any loss.
Integrated
exaust valve
Code
Maximum current
consumption
NO
PMExxx-Ex5xxx-xx
PMExxx-Ex7xxx-xx
0,150 A
SI
PMExxx-Ex6xxx-xx
PMExxx-Ex8xxx-xx
0,200 A
•
Efficiency curve
y = 0,1033x
0
1
2
3
4
5
6
7
8
9
10
11
0
10
20
30
40
50
60
70
80
90
100
Re
gu
lat
ed
p
re
ss
u
re
[
b
ar
]
Electrical control signal [%]
Efficiency curve 10,33 bar