Chapter 24: Alarms List
PoE Injector LEDs
phn-3963_004v000
Page 24-461
Alarm ID Type
Description
Severity
Probable Cause
Corrective Action
Notes
1781
Event
MRMC running script is
updated
Warning
New installed software
package does has an updated
version of the running MRMC
radio script
Reset the radio carrier to
reacquire the new updated
MRMC radio script
1790
Alarm
Hardware failure
Critical
An internal hardware failure
has been detected by the
system.
Replace the card or unit
reporting the hardware failure.
2100
Alarm
Loss of Signal on Line
Interface (LOS) on STM-
1/OC-3 port.
Critical
1.
Line is not properly
connected.
2.
External equipment is
faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external
equipment.
2101
Alarm
Loss of Frame on Line
Interface (LOF) on STM-
1/OC-3 port.
Major
1.
Line is not properly
connected.
2.
External equipment is
faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external
equipment.
2102
Alarm
Alarm Indication Signal on
Line Interface (MS-AIS/AIS-
L) received.
Minor
1.
Line is not properly
connected.
2.
External equipment is
faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external
equipment.
2103
Alarm
Remote Defect Indication
on Line Interface (MS-
RDI/RDI-L) received.
Minor
External equipment is faulty.
Check external equipment.
2104
Alarm
Loss of STM-1/OC-3 Frame
on Radio Interface.
Major
1.
All channels in Multi
Carrier ABC group are
down.
2.
Incorrect configuration on
remote side.
1.
Check link performance.
2.
Check radio alarms for
channel.
3.
Check configuration.