Chapter 24: Alarms List
PoE Injector LEDs
phn-3963_004v000
Page 24-449
Alarm ID Type
Description
Severity
Probable Cause
Corrective Action
Notes
102
Alarm
Loopback is active
Major
Ethernet loopback is active.
Wait till loopback timeout
expires or disable
loopback.
103
Alarm
Slot X port XX is
mirrored to slot Y port
YY
Minor
Mirroring is enabled by
user configuration.
Disable mirroring.
150
Alarm
Interface is down due to
automatic state
propagation.
Major
Failure of the radio interface
which is monitored for
automatic state propagation
causes automatic shutdown of
the controlled interface.
Check adjacent radio interface
for failure conditions that
caused automatic state
propagation.
200
Alarm
Protection communication
is down
Major
Mate unit is absent/failure.
Protection cable is
disconnected.
Unit failure.
1.
Check existence of mate
unit.
2.
Check protection cable
connection between units.
3.
Reset mate unit.
4.
Replace mate unit.
201
Alarm
Protection in Lockout
State
Major
202
Event
Protection switchover
due to local failure
Major
203
Alarm
Mate does not exist
Major
Mate does not exist or
cable unplugged.
401
Alarm
Ethernet Loss of Carrier
Major
Cable disconnected.
Defective cable.
1.
Check connection of cable
2.
Replace cable.
407
Event
Ethernet interface is up
Warning