EN
Page 10 / 44
GEO_Rev1 - Operating Instructions
The Warranty will not be considered in the following
cases:
- Whenever the use of the device does not conform
to the instructions and information described in this
manual.
-
In case of changes or variations made without
authorization of the manufacturer.
- In case of technical interventions executed by a non-
authorized personnel.
- In case of failing to carry out adequate maintenance.
1.5. Technical assistance
Any further information about the documentation,
technical assistance and spare parts, shall be
requested from: Calpeda S.p.A. (paragraph 1.2).
2. TECHNICAL DESCRIPTION
Medium-density polyethylene tank, resistant to
corrosion, with minimum overall dimensions.
-
GEO 40
single tank with 40 liters nominal capacity for
the installation of a GXRM type.
-
GEO 230
single tank with 230 liters nominal capacity
for the installation of an electropump type GM 10,
GQ, GX or GM series.
-
GEO 500
double tank with 500 liters nominal capacity
for the installation of two electropumps type GM 10,
GQ, GX or GM series.
2.1. Intended use
Automatic waste water collecting and lifting stations, to
handle domestic, civil and industrial waste water.
- clear water with GM 10, GXR, GQR pump series.
- waste water with GXV, GXC, GQS, GQV, GQN,
GMC, GMV pump series
- sewage water with grinder GQG pumps series
Refer to the specific manuals for information
concerning the electric pumps and electrical panels.
Do not use the station in explosive atmospheres or in
the presence of corrosive and/or flammable dust, acid
or gas, etc.
Do not use the station to pump hazardous, flammable
and/or explosive liquids.
Make sure the performance level of the lifting station
is compatible with the requirements of the system it is
connected to.
• Ambient temperature: M 0 °C / Maximum
+ 40 °C
• Maximum altitude: 1,000 metres a.s.l.
Liquid temperature from up to + 35 °C.
2.2. Improper use
The device is designed and built only for the purpose
described in paragraph 2.1.
Improper use of the device is forbidden, as is
use under conditions other than those indicated
in these instructions.
Improper use of the product reduces the safety and
the efficiency of the device, Calpeda shall not be
responsible for failure or accident due to improper use.
2.3. Marking
The following picture is a copy of the name-plate that is
on the external case of the product.
1 Type
11 Weight
15 AAAA Year of
manufacture
15 XXXX Serial
number
16 Certifications
XXXXXXX
AAAAXXXXX
XX kg
1
16
15
11
Montorso (VI) Italy IT 00142630243
Made in Italy
2.3.1. Pump Marking
The following picture is a copy of the name-plate of the
pump that is inside of the product.
1 Pump type
2 Delivery
3 Head
4 Rated power
5 Tension nominale
6 Nom. motor current
7 Notes
8 Frequency
9 Operation Duty
10 Insulation class
11 Weight
12 Power factor
13 Rotation speed rpm
14 Protection
15 AAAA Year of
manufacture
15 XXXX Serial
number
16 Certifications
17 Maximum
immersion depth
XXXXXXX
Q min/max X/X m
3
/h
AAAAXXXXX
H max/min X/X m
IP XX
n XXXX/min
220∆/380Y V3~50Hz
cosø X
X/X A
XXXXXXXX
S1 l.cl. X X kg
X kW (XHp) S.F.
1
2
3
4
5
6
7
8
9 10
16
15
14
17
13
12
11
X
m
Montorso (VI) Italy IT 00142630243
Made in Italy
3. TECHNICAL FEATURES
3.1. Technical data
Dimensions and weight (see chapter 12).
Nominal speed 2900/3450 rpm
Pump protection IP X8 (for continuous immersion)
Supply voltage / Frequency:
- up to 240V 1~ 50/60 Hz
- up to 480V 3~ 50/60 Hz
Check that the mains frequency and voltage
correspond to the electrical characteristics shown on
the indicator plate.
The electric data marked on the label are referred to
the nominal power of the motor.
Sound pressure: ≤ 75 dB (A), ≤ 80 dB (A) CA 91
.
Maximum starts/hour: 40 at regular intervals.
Maximum permissible pressure in the pump casing: 60
m (6 bar).
The max. inlet water pressure: PN (Pa) - Hmax (Pa).
3.2. Installation ambient for lifting station
The lifting stations can be installed on the ground or