4.  SAFETY
4.1. General provisions

  Before using the product it is necessary to 

know  all the safety indications.

Carefully read all operating instructions and the 

indications  defined  for  the  different  steps:  from 

transportation to disposal.

The specialized technicians must carefully comply 

with all applicable standards and laws, including local 

regulations of the country where the pump is sold.

The device has been built in conformity with the current 

safety laws. The improper use could damage people, 

animals and objects.

The manufacturer declines any liability in the event of 

damage due to improper use or use under conditions 

other than those indicated on the name-plate and in 

these instructions.

i

  Follow the routine maintenance schedules and 

the promptly replace damaged parts, this will 

allows the device to work in the best conditions.

Use only original spare parts provided from Calpeda 

S.p.A or from an authorized distributor.

  Don’t remove or change the labels placed on 

the device. 

Do not start the device in case of defects or damaged 

parts.

  Maintenance operations, requiring full or partial 

disassembly of the device, must be done only 

after disconnection from the supply.

4.2. Safety devices

The device has an external case that prevents any 

contact with internal parts.

4.3. Residual risks

The appliance, designed for use, when used in-line 

with the design and safety rules, doesn’t have residual 

risks.

4.4. Information and Safety signals

For this kind of product there will not be any signals 

on the product.

4.5. Individual protection devices

During installation, starting and maintenance it is 

suggested to the authorized operators to consider  

the use of individual protection devices suitable for 

described activities.

During ordinary and extraordinary maintenance 

interventions, safety gloves are required.

Signal  

individual protection device

    HAND PROTECTION

 

 

(gloves for protection against chemical, 

thermal and mechanical risks).

5.  TRANSPORTATION AND HANDLING

The product is packed to maintain the content intact.

During transportation avoid to stack excessive weights. 

Ensure that during the transportation the box cannot 

move.

It is not necessary to use any special vehicle to 

transport the packaged device.

The transport vehicles must comply, for the weight and 

dimensions, with the chosen product (see chapter 12).

5.1. Handling 

Handle with care, the packages must not receive 

impacts.

Avoid to impact onto the package materials that could 

damage the product.

If the weight exceeds 25 Kg the package must be 

handled by two person at the same time.

6.  INSTALLATION
6.1. Dimensions

For the dimensions of the device (see chapter 12).

6.2.  Ambient requirements and installation site 

dimensions

The customer has to prepare the installation site in 

order to guarantee the right installation and in order to 

fulfill the device requirements (electrical supply, etc...).

The place where the device will be installed must fulfill 

the requirements in the paragraph 3.2.

It's Absolutely forbidden to install the machine in an 

environment with potentially explosive atmosphere.

6.3. Unpacking

i

  

Inspect the device in order to check any 

damages which may have occurred during 

transportation.

Package material, once removed, must be discarded/

recycled according to local laws of the destination 

country.

6.4. Installation of the lifting station

For underground installation, extensions are available 

to bring the cover to ground level (max 2 extensions, 

see chapter 12). Access to the pump facilitated by a 

cover fixed with screws.

The lifting stations are fitted with several piping access 

points. 

Depending on the type of installation and current local 

regulations,  it  may  be  necessary  to  fit  a  trap,  check 

valve on the pipe connecting the system to the public/

private sewer or on other pipes. 

For installation, observe the laws, regulations, local 

and / or national standards in force in the country 

where the installation takes place.

Fit a check valve and an on/off valve upline and 

downline from the station (see chapter 12.1).

6.4.1. Pipes

Ensure the insides of pipes are clean and unobstructed 

before connection.

ATTENTION: The pipes connected to the pump 

should be secured to rest clamps so that they 

do not transmit stress, strain or vibrations to the 

pump.

 

Tighten the  pipes or union coupling to the extent 

sufficient to ensure a tight seal.

Excessive torque may cause damage to the pump.

The pipe diameters must not be smaller than the pump 

connections.

Summary of Contents for GEO

Page 1: ...tation automatique de relevage des eaux us es et d gout Estaci n autom tica de recogida y elevaci n de aguas sucias GEO ISTRUZIONI ORIGINALI PER L USO Pagina 2 Italiano OPERATING INSTRUCTIONS Page 9 E...

Page 2: ...enti per la corretta gestione dell apparecchio e dei suoi componenti Interventi che possono essere svolti dall utilizzatore finale dell apparecchio Previa lettura delle istruzioni e il responsabile pe...

Page 3: ...mpiego dell apparecchio per usi impropri e modalit di uso non previste dal presente manuale L utilizzo improprio del prodotto deteriora le caratteristiche di sicurezza e di efficienza dell apparecchio...

Page 4: ...ari mezzi per trasportare l apparecchio imballato I mezzi per trasportare il prodotto imballato devono essere adeguati alle dimensioni e ai pesi del prodotto scelto vedi capitolo 12 5 1 Movimentazione...

Page 5: ...Prevedete idonei sistemi che segnalino la presenza della stazione per evitare possibili danni causati inavvertitamente Garantite uno spazio sufficiente all installazione e manutenzione attorno e sopr...

Page 6: ...cate il corretto funzionamento della stazione Il flusso di liquido proveniente dalle varie utenze non deve ostacolare il corretto funzionamento dei galleggianti presenti nel serbatoio Prima dell insta...

Page 7: ...p A 8 1 Manutenzione ordinaria OFF Prima di ogni intervento di manutenzione togliere l alimentazione elettrica e assicurarsi che la pompa non rischi di essere messa sotto tensione per inavvertenza Ch...

Page 8: ...ompa b Cuscinetti bloccati a Se si in grado smontare il corpo pompa e rimuovere i corpi solidi estranei all interno della girante se necessario rivolgersi a ad un centro assistenza autorizzato b Nel c...

Page 9: ...hine and its parts Operations that could be performed by the final user After carefully reading of the instructions is responsible for maintenance under normal conditions They are authorized to affect...

Page 10: ...Improper use The device is designed and built only for the purpose described in paragraph 2 1 Improper use of the device is forbidden as is use under conditions other than those indicated in these ins...

Page 11: ...during the transportation the box cannot move It is not necessary to use any special vehicle to transport the packaged device The transport vehicles must comply for the weight and dimensions with the...

Page 12: ...idental damage Leave enough space around and above the lifting station for installation and maintenance purposes Provide for enough space all around the control panel for natural cooling This electric...

Page 13: ...of the impeller is as shown by the arrow on the pump Otherwise disconnect electrical power and reverse the connections of two phases in the control box Operation with wrong direction of rotation will...

Page 14: ...ce activity It is suggested to make an inspections at least every 6 months The inspection must include 1 Rinse with clean water from inside the station 2 Rinse the level floats with clean water piezom...

Page 15: ...2a If possible dismantle the pump casing and remove any solid foreign bodies inside the rotor if necessary contact an authorised service centre 2b If the bearings are damaged replace them or if necess...

Page 16: ...vertissements pour g rer correctement l appareil et ses l ments Interventions que l utilisateur final de l appareil a le droit de r aliser Apr s avoir lu les instructions est responsable de l entretie...

Page 17: ...visible L appareil a t con u et construit exclusivement pour l emploi pr vu d crit au par 2 1 Il est interdit d employer l appareil pour des utilisations impropres et selon des modalit s non pr vues...

Page 18: ...PORT ET MANUTENTION Le produit est emball pour en pr server le contenu Pendant le transport viter d y superposer des poids excessifs S assurer que la boite ne puisse bouger pendant le transport Les mo...

Page 19: ...ation enterr e la station est en mesure de supporter une charge de passage de 100 kg Pour faciliter les op rations de maintenance la fosse peut tre ferm e au moyen d une dalle tampon ou de tout autre...

Page 20: ...fonctionnement de la station Le flux de liquide provenant des diff rents utilisateurs ne doit pas interf rer avec le fonctionnement des flotteurs situ s dans le r servoir Pour les lectropompes triphas...

Page 21: ...Avant toute intervention de maintenance couper l alimentation lectrique et s assurer que la pompe ne risque pas d tre mise sous tension par inadvertance Fermer les vannes d isolation d aspiration et...

Page 22: ...qu s a Si possible d monter le corps de pompe et extraire tous les composants trangers solides si n cessaire contacter le revendeur b Si les roulements sont endommag s les remplacer et si n cessaire c...

Page 23: ...omponentes Intervenciones que pueden ser realizadas s lo por el usuario final del dispositivo Despu s de leer las instrucciones es responsable de su mantenimiento en condiciones normales de uso Est au...

Page 24: ...est n indicados en este manual El uso impropio del producto deteriora las caracter sticas de seguridad y de eficiencia del dispositivo Calpeda no se hace responsable para da os o perjuicios causados p...

Page 25: ...sporte del aparato embalado Los medios para el transporte del aparato embalado deben ser adecuados a las dimensiones y a los pesos del producto elegido ver capitolo 12 5 1 Manejo Manejar con cuidado e...

Page 26: ...acilitar el mantenimiento Instalar sistemas adecuados para se alar la presencia de la estaci n y evitar los posibles da os que se podr an ocasionar inadvertidamente Asegurar un espacio suficiente para...

Page 27: ...estaci n El flujo de l quido que procede de las diferentes instalaciones no debe obstaculizar el correcto funcionamiento de los interruptores de flotador presentes en la estaci n Antes de la instalac...

Page 28: ...antenimiento del dispositivo p ngase en contacto con CALPEDA S p A 8 1 Mantenimiento ordinario OFF Antes de cualquier operaci n de mantenimiento desconecte la fuente de alimentaci n y aseg rese de que...

Page 29: ...r los cuerpos s lidos ajenos en el interior del rodete si es necesario dirigirse a un centro de asistencia autorizado b En el caso se hayan da ados los cojinetes sustituirlos o si es necesario dirigir...

Page 30: ...kg 6 GEO 40 A Arrangement for 40 mm inlet 40 mm outlet 25 mm relief B Cable passage with Shuko plug A Predisposici n para Entrada 40 mm Impulsi n 40 mm Salida de aire 25 mm B Salida cable con con clav...

Page 31: ...A C Ingresso o sfiato B Uscita per mandata D Uscita per scarico G 1 1 2 E Uscita cavo A C Entr e et Ventilation B Orifice de sortie D G 1 1 2 vidange E Sortie c ble de pompe A C inlet and relief B del...

Page 32: ...livery outlet D G 1 1 2 draining outlet E Cable outlet A C Entr e et Ventilation B Orifice de sortie D G 1 1 2 vidange E Sortie c ble de pompe A C Entrada o salida de aire B Salida impulsi n D Salida...

Page 33: ...ur demande 1 pompe avec 10 m de c ble It includes 1 tank capacity 40 l 1 single phase pump with 5 m cable and float switch 1 non return valve with clapet on the pump delivery side 1 discharge pipe kit...

Page 34: ...with 10 m cable 1 discharge pipe kit in PVC with a ball valve and non return ball valve 1 support kit with safety float switch and auto supplied control panel for remote alarm with horn and flashing l...

Page 35: ...on 1 discharge pipe kit in PVC with a ball valve and non return ball valve On demand 1 safety float switch with support for single phase version and autosupplied control panel for remote alarm with ho...

Page 36: ...nd auto supplied control panel for remote alarm with horn and flashing light extention 300 mm Incluye 1 dep sito con capacidad de 230 litros 1 bomba monof sica con 10 m de cable sin interruptor de niv...

Page 37: ...PVC On demand 2 discharge pipe kit in PVC with a ball valve and non return ball valve 1 safety float switch and auto supplied control panel for remote alarm with horn and flashing light extention 300...

Page 38: ...scharge pipe kit in PVC with a ball valve and non return ball valve On demand 1 safety float switch and auto supplied control panel for remote alarm with horn and flashing light extention 300 mm Inclu...

Page 39: ...h horn and flashing light extention 300 mm Incluye 1 dep sito con capacidad de 500 litros 2 bombas monof sicas con 10 m de cable sin interruptor de nivel trif sicas con 10 m de cable 1 kit varilla con...

Page 40: ...40 44 GEO_Rev1 12 2 Esempi di installazione interrata Underground Installation examples Exemples d installation sous terre Ejemplos de instalaci n bajo tierra Fig 1...

Page 41: ...getale 5 Pozzo depressione 6 Tubo drenaggio 1 Terre 2 Sable 3 Gravier 4 Terreau v g tal 5 Eh bien la d pression 6 Tuyau d vacuation 1 Ground 2 Sand 3 Gravel 4 Vegetable ground 5 Decompression wells 6...

Page 42: ...2014 30 EU 2014 35 EU DK OVERENSSTEMMELSESERKL RING Vi CALPEDA S p A erkl rer hermed at vore produkten GEO 40 GEO 230 GEO 500 pumpe type og serie nummer vist p typeskiltet er fremstillet i overensstem...

Page 43: ...Electrical Equipment Safety Regulations 2016 Electromagnetic Compatibility Regulations 2016 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulation...

Page 44: ...Calpeda s p a Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia Tel 39 0444 476476 E mail info calpeda it www calpeda com...

Reviews: