background image

EN

GEO_Rev1 - Operating Instructions

Page 9 / 44

THIS INSTRUCTION MANUAL IS THE PROPERTY 

OF CALPEDA S.P.A. ANY REPRODUCTION, EVEN 

IF PARTIAL, IS FORBIDDEN

1.  GENERAL INFORMATION

Before using the product carefully read the information 

contained in this instruction manual and that included 

in the pump manual, the manual should be kept for 

future reference.

Italian is the original language of this instruction 

manual, this language is the reference language in 

case of discrepancies in the translations.

This manual is part of the essential safety requirement 

and  must  be  retained  until  the  product  is  finally  de-

commissioned.

The customer, in case of loss, can request a copy 

of the manual by contacting Calpeda S.p.A. or their 

agent, specifying the type of product data shown on 

the label of the machine (see 2.3 Marking)

Any changes, alterations or modifications made to the 

product or part of it, not authorized by the manufacturer, 

will revoke the “CE declaration” and warranty.

This appliance should not be operated 

by children younger than 8 years, 

people with reduced physical, sensory 

or mental capacities, or inexperienced 

people who are not familiar with the 

product, unless they are given close 

supervision or instructions on how to 

use it safely and are made aware by a 

responsible person of the dangers its 

use might entail.

Children must not play with the 

appliance.

It is the user's responsibility to clean 

and maintain the appliance. Children 

should never clean or maintain it 

unless they are given supervision.

1.1. Symbols

To improve the understanding of the manual, below are 

indicated the symbols used with the related meaning.

 

 

Information and warnings that must be 

observed, otherwise there is a risk that the 

machine could damage or compromise 

personnel safety.

  The failure to observe electrical information 

and warnings, could damage the machine or 

compromise personnel safety.

i

  Notes and warnings for the correct management 

of the machine and its parts.

   Operations that could be performed by the final 

user. After carefully reading of the instructions, 

is responsible for maintenance under normal 

conditions. They are authorized to affect 

standard maintenance operations.

  

Operations that must be performed by a 

qualified  electrician.  Specialized  technician 

authorised to affect all electrical operations 

including maintenance. They are able to 

operate with in the presence of high voltages.

  Operations that must be done performed by 

a  qualified  technician.  Specialized  technician 

able to install the device, under normal 

conditions, working during “maintenance”, 

and allowed to do electrical and mechanical 

interventions for maintenance. They must 

be capable of executing simple electrical 

and mechanical operations related to the 

maintenance of the device.

  Indicates that it is mandatory to use individual 

protection devices.

OFF

  Operations that must be done with the device 

switched off and disconnected from the power 

supply.

ON

  Operations that must be done with the device 

switched on.

1.2. Manufacturer name and address

Manufacturer name: Calpeda S.p.A.

Address: Via Roggia di Mezzo, 39

36050 Montorso Vicentino - Vicenza / Italia

www.calpeda.it

1.3. Authorized operators

The product is intended for use by expert operators 

divided into end users and specialized technicians. 

(see the symbols above).

i

  

It’s forbidden, for the end user, carry out 

operations which must be done only by 

specialized technicians. The manufacturer 

declines any liability  for damage related to the 

non-compliance of this warning.

1.4. Warranty

For the product warranty refer to the general terms and 

conditions of sale. 

i

  The warranty covers only the replacement and 

the repair of the defective parts of the goods 

(recognized by the manufacturer).

SUMMARY

1.  GENERAL INFORMATION ............................. 9

2.  TECHNICAL DESCRIPTION ........................ 10

3.  TECHNICAL FEATURES .............................. 10

4. SAFETY ........................................................ 11

5. 

TRANSPORTATION AND HANDLING ......... 11

6. INSTALLATION ............................................. 11

7. 

STARTUP AND OPERATION ....................... 13

8. MAINTENANCE ............................................14

9. DISPOSAL ....................................................14

10.  SPARE PARTS .............................................14

11. TROUBLESHOOTING ..................................15

12   Dimensions and weights ............................... 30

12.1. Construction  .................................................33

12.2. Underground Installation examples .............. 40

Declaration of conformity .......................................42

Summary of Contents for GEO

Page 1: ...tation automatique de relevage des eaux us es et d gout Estaci n autom tica de recogida y elevaci n de aguas sucias GEO ISTRUZIONI ORIGINALI PER L USO Pagina 2 Italiano OPERATING INSTRUCTIONS Page 9 E...

Page 2: ...enti per la corretta gestione dell apparecchio e dei suoi componenti Interventi che possono essere svolti dall utilizzatore finale dell apparecchio Previa lettura delle istruzioni e il responsabile pe...

Page 3: ...mpiego dell apparecchio per usi impropri e modalit di uso non previste dal presente manuale L utilizzo improprio del prodotto deteriora le caratteristiche di sicurezza e di efficienza dell apparecchio...

Page 4: ...ari mezzi per trasportare l apparecchio imballato I mezzi per trasportare il prodotto imballato devono essere adeguati alle dimensioni e ai pesi del prodotto scelto vedi capitolo 12 5 1 Movimentazione...

Page 5: ...Prevedete idonei sistemi che segnalino la presenza della stazione per evitare possibili danni causati inavvertitamente Garantite uno spazio sufficiente all installazione e manutenzione attorno e sopr...

Page 6: ...cate il corretto funzionamento della stazione Il flusso di liquido proveniente dalle varie utenze non deve ostacolare il corretto funzionamento dei galleggianti presenti nel serbatoio Prima dell insta...

Page 7: ...p A 8 1 Manutenzione ordinaria OFF Prima di ogni intervento di manutenzione togliere l alimentazione elettrica e assicurarsi che la pompa non rischi di essere messa sotto tensione per inavvertenza Ch...

Page 8: ...ompa b Cuscinetti bloccati a Se si in grado smontare il corpo pompa e rimuovere i corpi solidi estranei all interno della girante se necessario rivolgersi a ad un centro assistenza autorizzato b Nel c...

Page 9: ...hine and its parts Operations that could be performed by the final user After carefully reading of the instructions is responsible for maintenance under normal conditions They are authorized to affect...

Page 10: ...Improper use The device is designed and built only for the purpose described in paragraph 2 1 Improper use of the device is forbidden as is use under conditions other than those indicated in these ins...

Page 11: ...during the transportation the box cannot move It is not necessary to use any special vehicle to transport the packaged device The transport vehicles must comply for the weight and dimensions with the...

Page 12: ...idental damage Leave enough space around and above the lifting station for installation and maintenance purposes Provide for enough space all around the control panel for natural cooling This electric...

Page 13: ...of the impeller is as shown by the arrow on the pump Otherwise disconnect electrical power and reverse the connections of two phases in the control box Operation with wrong direction of rotation will...

Page 14: ...ce activity It is suggested to make an inspections at least every 6 months The inspection must include 1 Rinse with clean water from inside the station 2 Rinse the level floats with clean water piezom...

Page 15: ...2a If possible dismantle the pump casing and remove any solid foreign bodies inside the rotor if necessary contact an authorised service centre 2b If the bearings are damaged replace them or if necess...

Page 16: ...vertissements pour g rer correctement l appareil et ses l ments Interventions que l utilisateur final de l appareil a le droit de r aliser Apr s avoir lu les instructions est responsable de l entretie...

Page 17: ...visible L appareil a t con u et construit exclusivement pour l emploi pr vu d crit au par 2 1 Il est interdit d employer l appareil pour des utilisations impropres et selon des modalit s non pr vues...

Page 18: ...PORT ET MANUTENTION Le produit est emball pour en pr server le contenu Pendant le transport viter d y superposer des poids excessifs S assurer que la boite ne puisse bouger pendant le transport Les mo...

Page 19: ...ation enterr e la station est en mesure de supporter une charge de passage de 100 kg Pour faciliter les op rations de maintenance la fosse peut tre ferm e au moyen d une dalle tampon ou de tout autre...

Page 20: ...fonctionnement de la station Le flux de liquide provenant des diff rents utilisateurs ne doit pas interf rer avec le fonctionnement des flotteurs situ s dans le r servoir Pour les lectropompes triphas...

Page 21: ...Avant toute intervention de maintenance couper l alimentation lectrique et s assurer que la pompe ne risque pas d tre mise sous tension par inadvertance Fermer les vannes d isolation d aspiration et...

Page 22: ...qu s a Si possible d monter le corps de pompe et extraire tous les composants trangers solides si n cessaire contacter le revendeur b Si les roulements sont endommag s les remplacer et si n cessaire c...

Page 23: ...omponentes Intervenciones que pueden ser realizadas s lo por el usuario final del dispositivo Despu s de leer las instrucciones es responsable de su mantenimiento en condiciones normales de uso Est au...

Page 24: ...est n indicados en este manual El uso impropio del producto deteriora las caracter sticas de seguridad y de eficiencia del dispositivo Calpeda no se hace responsable para da os o perjuicios causados p...

Page 25: ...sporte del aparato embalado Los medios para el transporte del aparato embalado deben ser adecuados a las dimensiones y a los pesos del producto elegido ver capitolo 12 5 1 Manejo Manejar con cuidado e...

Page 26: ...acilitar el mantenimiento Instalar sistemas adecuados para se alar la presencia de la estaci n y evitar los posibles da os que se podr an ocasionar inadvertidamente Asegurar un espacio suficiente para...

Page 27: ...estaci n El flujo de l quido que procede de las diferentes instalaciones no debe obstaculizar el correcto funcionamiento de los interruptores de flotador presentes en la estaci n Antes de la instalac...

Page 28: ...antenimiento del dispositivo p ngase en contacto con CALPEDA S p A 8 1 Mantenimiento ordinario OFF Antes de cualquier operaci n de mantenimiento desconecte la fuente de alimentaci n y aseg rese de que...

Page 29: ...r los cuerpos s lidos ajenos en el interior del rodete si es necesario dirigirse a un centro de asistencia autorizado b En el caso se hayan da ados los cojinetes sustituirlos o si es necesario dirigir...

Page 30: ...kg 6 GEO 40 A Arrangement for 40 mm inlet 40 mm outlet 25 mm relief B Cable passage with Shuko plug A Predisposici n para Entrada 40 mm Impulsi n 40 mm Salida de aire 25 mm B Salida cable con con clav...

Page 31: ...A C Ingresso o sfiato B Uscita per mandata D Uscita per scarico G 1 1 2 E Uscita cavo A C Entr e et Ventilation B Orifice de sortie D G 1 1 2 vidange E Sortie c ble de pompe A C inlet and relief B del...

Page 32: ...livery outlet D G 1 1 2 draining outlet E Cable outlet A C Entr e et Ventilation B Orifice de sortie D G 1 1 2 vidange E Sortie c ble de pompe A C Entrada o salida de aire B Salida impulsi n D Salida...

Page 33: ...ur demande 1 pompe avec 10 m de c ble It includes 1 tank capacity 40 l 1 single phase pump with 5 m cable and float switch 1 non return valve with clapet on the pump delivery side 1 discharge pipe kit...

Page 34: ...with 10 m cable 1 discharge pipe kit in PVC with a ball valve and non return ball valve 1 support kit with safety float switch and auto supplied control panel for remote alarm with horn and flashing l...

Page 35: ...on 1 discharge pipe kit in PVC with a ball valve and non return ball valve On demand 1 safety float switch with support for single phase version and autosupplied control panel for remote alarm with ho...

Page 36: ...nd auto supplied control panel for remote alarm with horn and flashing light extention 300 mm Incluye 1 dep sito con capacidad de 230 litros 1 bomba monof sica con 10 m de cable sin interruptor de niv...

Page 37: ...PVC On demand 2 discharge pipe kit in PVC with a ball valve and non return ball valve 1 safety float switch and auto supplied control panel for remote alarm with horn and flashing light extention 300...

Page 38: ...scharge pipe kit in PVC with a ball valve and non return ball valve On demand 1 safety float switch and auto supplied control panel for remote alarm with horn and flashing light extention 300 mm Inclu...

Page 39: ...h horn and flashing light extention 300 mm Incluye 1 dep sito con capacidad de 500 litros 2 bombas monof sicas con 10 m de cable sin interruptor de nivel trif sicas con 10 m de cable 1 kit varilla con...

Page 40: ...40 44 GEO_Rev1 12 2 Esempi di installazione interrata Underground Installation examples Exemples d installation sous terre Ejemplos de instalaci n bajo tierra Fig 1...

Page 41: ...getale 5 Pozzo depressione 6 Tubo drenaggio 1 Terre 2 Sable 3 Gravier 4 Terreau v g tal 5 Eh bien la d pression 6 Tuyau d vacuation 1 Ground 2 Sand 3 Gravel 4 Vegetable ground 5 Decompression wells 6...

Page 42: ...2014 30 EU 2014 35 EU DK OVERENSSTEMMELSESERKL RING Vi CALPEDA S p A erkl rer hermed at vore produkten GEO 40 GEO 230 GEO 500 pumpe type og serie nummer vist p typeskiltet er fremstillet i overensstem...

Page 43: ...Electrical Equipment Safety Regulations 2016 Electromagnetic Compatibility Regulations 2016 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulation...

Page 44: ...Calpeda s p a Via Roggia di Mezzo 39 36050 Montorso Vicentino Vicenza Italia Tel 39 0444 476476 E mail info calpeda it www calpeda com...

Reviews: