199
I-Modell - 13/14 - Ausgabe 08/13 - 2354644 - BUE-0056-07EN
Appliances
9
230 V operation
If the "AES" operating mode is set and the 230 V supply is connected, the AES
selects this energy source first.
12 V operation
If the "AES" operating mode is set, the AES only selects 12 V operation if the
vehicle engine is running (alternator signal D+).
Gas operation
If the "AES" operating mode is set, the 230 V supply is
not
connected and the
vehicle engine is
switched off
, the AES selects the gas supply. When
selecting gas operation the ignition fuse is opened automatically so gas can
get into the burner. At the same time the electronic ignition is activated. If the
gas flame is extinguished, e.g. by blast of wind, the ignition is activated imme-
diately and re-ignites the gas. If there is a fault in gas operation, the illuminated
buttons "Gas" (Fig. 218,3) and "Fault" (Fig. 218,9) flash. The "Fault" indicator
lamp (Fig. 218,10) lights up and an alarm sounds for 20 seconds.
Change-over between
energy sources
Z
The refrigerator always requires a 12 V control voltage, regardless of which
type of energy it is using. The control voltage is drawn from the living room
area battery. Therefore the closed circuit current always flows even if the
refrigerator is switched off. Always disconnect the refrigerator from the bat-
tery for a temporary lay-up.
Fig. 218 Operating controls for the refrigerator (Dometic RMD)
1
On/Off key
2
Illuminated button for "230 V" mode
3
Illuminated button for "Gas" mode
4
Illuminated button for "12 V" mode
5
Illuminated button for "AES" mode (automatic power selection)
6
Illuminated button for frame heater
7
Temperature range selection button
8
Temperature ranges display
9
Illuminated button for "Fault"/"Reset" in gas mode
10 "Fault" indicator lamp (visible when the refrigerator door is closed)
11 "Operating" indicator lamp (visible when the refrigerator door is closed)
X
Never let gas escape unburned due to danger of explosion.
Z
If LPG is used, the gas burner must be cleaned more frequently.
Z
Open the regulator tap on the gas bottle and the gas isolator tap "Refriger-
ator".
X
Open flames are prohibited at petrol stations. If the stop takes longer
than 15 minutes, the refrigerator has to be turned off at the energy
selector switch.
Summary of Contents for I 690 G
Page 2: ...I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Instruction manual ...
Page 8: ...Contents 8 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN ...
Page 18: ...18 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Safety 2 ...
Page 120: ...120 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Gas system 7 ...
Page 254: ...254 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Wheels and tyres 13 ...
Page 268: ...268 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Troubleshooting 14 ...
Page 272: ...272 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Special equipment 15 ...
Page 290: ...290 I Modell 13 14 Ausgabe 08 13 2354644 BUE 0056 07EN Helpful notes 17 ...