64
of 216
6.1.16 PROFIBUS settings (option)
Note:
The "PROFIBUS" menu (M54) only exists if your DIGIFORCE
®
9311 is installed with option
Vxxx2.
Diagram 28: PROFIBUS settings
Parameters in the "PROFIBUS" menu (M54)
SW version
Firmware version of the PROFIBUS Fieldbus module
Serial number
Serial number of the Fieldbus module
Control via
PROFIBUS
: the DIGIFORCE
®
9311 responds solely to control signals
(inputs) from the PROFIBUS interface.
PLC
: the DIGIFORCE
®
9311 responds solely to control signals (inputs)
from the PLC I/O interface.
When control via PLC I/O is selected, data is still transferred using the
cyclical PROFIBUS DP-V0 protocol.
Station address
Enter here the PROFIBUS address for the instrument.
Valid address range: 1 to 126.
Cyclical data
Displays the active mode in the cyclical PROFIBUS DP-V0 service.
Details are provided in a separate document: The DIGIFORCE
®
9311
PROFIBUS manual.
Note:
Details of the PROFIBUS interface are provided in a separate document: "The
DIGIFORCE
®
9311 PROFIBUS manual".
Summary of Contents for DIGIFORCE 9311